Comparison of Photon Dose Distribution in Breast Cancer Using 3DCRT and Half Beam Techniques

Radiotherapy planning can be done with 3D Conformal Radiotherapy (3DCRT) and Half Beam. The success of radiotherapy planning is considered by comparing the isodose curve, Dose Volume Histogram (DVH), Organs At Risk (OAR), Homogeneity Index (HI), and Conformity Index (CI) obtained by the 3DCRT and Half Beam techniques. This study used data from 5 patients at the Radiotherapy Installation at A.W. Hospital. Sjahranie Samarinda with radiation planning of 5000 cGy (25×2 Gy) for breast cancer. The two radiation plans used gantry angles of 310˚ and 120˚. The calculated dose distribution value can be seen through the 90%, 95% PTV dose, and OAR absorbed dose. PTV doses of 90% and 95% in the 3DCRT technique covered the target well. The radiation dose values of the 3DCRT technique at PTV 90% were around 4860 cGy – 4930 cGy and PTV 95% were around 4750 cGy – 4840 cGy. Meanwhile, the Half Beam technique could not cover the target well. It was because the radiation dose values received by the Half Beam technique at 90% PTV were around 780 cGy – 4860 cGy and 95% PTV were around 2210 cGy – 5020 cGy. The OAR absorbed doses values for the 3DCRT and Half Beam techniques were still within the safe limits of tolerance according to QUANTEC. Meanwhile, the HI and CI values in the 3DCRT technique were closer to the rules of ICRU Report 83 of 2010 compared to the Half Beam technique. Therefore, from the values that have been obtained, the success rate of the radiotherapy planning process after measurements is shown in the 3DCRT technique. It has the value of more efficient dose calculations and can be used as a reference in optimizing dose distribution to patients.

Authors

Institutions

Publication Details

Journal
Jurnal Inotera
Published
2024-09-02
DOI
https://doi.org/10.31572/inotera.vol9.iss2.2024.id359
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Photon Dose Distribution in Breast Cancer Using 3DCRT and Half Beam Techniques

Erlinda Ratnasari Putri, Robert Janssen Stevenly, Rahmawati Munir, Nurrohimawati Yusrani
Jurnal Inotera
Advanced Radiotherapy Techniques
article

Comparison of Photon Dose Distribution in Breast Cancer Using 3DCRT and Half Beam Techniques

Erlinda Ratnasari Putri, Robert Janssen Stevenly, Rahmawati Munir, Nurrohimawati Yusrani
article en

Abstract

Radiotherapy planning can be done with 3D Conformal Radiotherapy (3DCRT) and Half Beam. The success of radiotherapy planning is considered by comparing the isodose curve, Dose Volume Histogram (DVH), Organs At Risk (OAR), Homogeneity Index (HI), and Conformity Index (CI) obtained by the 3DCRT and Half Beam techniques. This study used data from 5 patients at the Radiotherapy Installation at A.W. Hospital. Sjahranie Samarinda with radiation planning of 5000 cGy (25×2 Gy) for breast cancer. The two radiation plans used gantry angles of 310˚ and 120˚. The calculated dose distribution value can be seen through the 90%, 95% PTV dose, and OAR absorbed dose. PTV doses of 90% and 95% in the 3DCRT technique covered the target well. The radiation dose values of the 3DCRT technique at PTV 90% were around 4860 cGy – 4930 cGy and PTV 95% were around 4750 cGy – 4840 cGy. Meanwhile, the Half Beam technique could not cover the target well. It was because the radiation dose values received by the Half Beam technique at 90% PTV were around 780 cGy – 4860 cGy and 95% PTV were around 2210 cGy – 5020 cGy. The OAR absorbed doses values for the 3DCRT and Half Beam techniques were still within the safe limits of tolerance according to QUANTEC. Meanwhile, the HI and CI values in the 3DCRT technique were closer to the rules of ICRU Report 83 of 2010 compared to the Half Beam technique. Therefore, from the values that have been obtained, the success rate of the radiotherapy planning process after measurements is shown in the 3DCRT technique. It has the value of more efficient dose calculations and can be used as a reference in optimizing dose distribution to patients.

Jurnal InoteraVol. 9(2)
Mulawarman University (ID)
Good health and well-being
Openalex Percentile: Top 82%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.