Assessment of the Impact of Direct Water Cooling and Cleaning System Operating Scenarios on PV Panel Performance

Among the various renewable energy-based technologies, photovoltaic panels are characterized by a high rate of development and application worldwide. Many efforts have been made to study innovative materials to improve the performance of photovoltaic cells. However, the most commonly used crystalline panels also have significant potential to enhance their energy yield by providing cooling and cleaning solutions. This paper discusses the possibility of introducing a dedicated direct-water cooling and cleaning system. As assumed, detailed schedules of the operation of the developed direct water cooling and cleaning system should be fitted to actual weather conditions. In this context, different cooling strategies were proposed and tested, including different intervals of opening and closing water flow. All tests were conducted using a dedicated experimental rig. 70 Wp monocrystalline panels were tested under laboratory conditions and 160 Wp polycrystalline panels were tested under real conditions. The results showed that introducing a scenario with a 1-min cooling and a 5-min break allowed for proving the panel’s surface temperature lower than 40 °C. In comparison, the temperature of the uncooled panel under the same operating conditions was close to 60 °C. Consequently, an increase in power generation was observed. The maximum power increase was observed in July and amounted to 15.3%. On the other hand, considering selected weeks in May, July, and September, the average increase in power generation was 3.63%, 7.48%, and 2.51%, respectively. It was concluded that the division of photovoltaic installation allows reasonable operating conditions for photovoltaic panels with a lower amount of energy consumed to power water pumps.

Authors

Institutions

Publication Details

Journal
Energies
Published
2024-09-02
DOI
https://doi.org/10.3390/en17174392
Citations
5
Primary Topic
Solar Thermal and Photovoltaic Systems
Type
article
Field-Weighted Citation Impact
0.51

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of the Impact of Direct Water Cooling and Cleaning System Operating Scenarios on PV Panel Performance

Krzysztof Sornek
5 citations
Energies
Solar Thermal and Photovoltaic Systems
0.51
article

Assessment of the Impact of Direct Water Cooling and Cleaning System Operating Scenarios on PV Panel Performance

Krzysztof Sornek
article en
5 citations

Abstract

Among the various renewable energy-based technologies, photovoltaic panels are characterized by a high rate of development and application worldwide. Many efforts have been made to study innovative materials to improve the performance of photovoltaic cells. However, the most commonly used crystalline panels also have significant potential to enhance their energy yield by providing cooling and cleaning solutions. This paper discusses the possibility of introducing a dedicated direct-water cooling and cleaning system. As assumed, detailed schedules of the operation of the developed direct water cooling and cleaning system should be fitted to actual weather conditions. In this context, different cooling strategies were proposed and tested, including different intervals of opening and closing water flow. All tests were conducted using a dedicated experimental rig. 70 Wp monocrystalline panels were tested under laboratory conditions and 160 Wp polycrystalline panels were tested under real conditions. The results showed that introducing a scenario with a 1-min cooling and a 5-min break allowed for proving the panel’s surface temperature lower than 40 °C. In comparison, the temperature of the uncooled panel under the same operating conditions was close to 60 °C. Consequently, an increase in power generation was observed. The maximum power increase was observed in July and amounted to 15.3%. On the other hand, considering selected weeks in May, July, and September, the average increase in power generation was 3.63%, 7.48%, and 2.51%, respectively. It was concluded that the division of photovoltaic installation allows reasonable operating conditions for photovoltaic panels with a lower amount of energy consumed to power water pumps.

EnergiesVol. 17(17)
AGH University of Krakow (PL)
Akademia Górniczo-Hutnicza im. Stanislawa Staszica
Openalex Percentile: Top 43%
Solar Thermal and Photovoltaic Systems
0.51
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Assessment of the Impact of Direct Water Cooling and Cleaning System Operating Scenarios on PV Panel Performance — Krzysztof Sornek · Energies (2024) | TGRS Research Map | TGRS