Active and passive electronic interfaces adapted to a capacitive micromachined ultrasonic transducer (CMUT) used in acoustic energy transfer

Wireless power transfer is a key feature in the field of biomedical engineering. It allows a reduction of the energy storage devices in medical implants. An efficient way to safely transfer energy to medical implants is to convey ultrasounds through the body to a Capacitive Micromachined Ultrasonic Transducer (CMUT). For an application of ultrasonic energy transfer through skin, the present work compares the efficiency of two different electronic architectures to receive energy from an array of CMUT. The well known Synchronous Switch Harvesting on Inductor (SSHI) is compared in simulation to a simple impedance matching. Indeed, for an ultrasonic energy transfer, the high excitation frequency (1–8 MHz) allows the use of an inductor matching the CMUT’s clamped capacitor. The simplicity of an impedance matching circuit, its low volume and its efficiency makes it the best choice for an efficient energy transfer process to the targeted load. The CMUT model used in the simulations is a mason’s model which component values are extracted from the impedance measurement of a real device. In the end, the impedance matching is experimentally tested on this same device and compared to the simulation. A maximum 4,5 mW power is transferred to an optimal load for an input ultrasound pressure of 90 kPa. • An impedance measurement of a real device enables the computation of a precise simulation model. • Both active and passive electronic interfaces can transfer the maximum energy to the load. • A 4.5 mW power is transferred to a DC load with only a matching inductor a diode bridge and a 90 kPa incident pressure.

Authors

Institutions

Publication Details

Journal
Sensors and Actuators A Physical
Published
2024-09-02
DOI
https://doi.org/10.1016/j.sna.2024.115856
Citations
3
Primary Topic
Innovative Energy Harvesting Technologies
Type
article
Field-Weighted Citation Impact
0.64

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Active and passive electronic interfaces adapted to a capacitive micromachined ultrasonic transducer (CMUT) used in acoustic energy transfer

Guylaine Poulin‐Vittrant, Paul Roche, Dominique Certon, Kevin Nadaud et al.
3 citations
Sensors and Actuators A Physical
Innovative Energy Harvesting Technologies
0.64
article

Active and passive electronic interfaces adapted to a capacitive micromachined ultrasonic transducer (CMUT) used in acoustic energy transfer

Guylaine Poulin‐Vittrant, Paul Roche, Dominique Certon, Kevin Nadaud, Samuel Callé, Jean-Charles Lebunetel
article en
3 citations

Abstract

Wireless power transfer is a key feature in the field of biomedical engineering. It allows a reduction of the energy storage devices in medical implants. An efficient way to safely transfer energy to medical implants is to convey ultrasounds through the body to a Capacitive Micromachined Ultrasonic Transducer (CMUT). For an application of ultrasonic energy transfer through skin, the present work compares the efficiency of two different electronic architectures to receive energy from an array of CMUT. The well known Synchronous Switch Harvesting on Inductor (SSHI) is compared in simulation to a simple impedance matching. Indeed, for an ultrasonic energy transfer, the high excitation frequency (1–8 MHz) allows the use of an inductor matching the CMUT’s clamped capacitor. The simplicity of an impedance matching circuit, its low volume and its efficiency makes it the best choice for an efficient energy transfer process to the targeted load. The CMUT model used in the simulations is a mason’s model which component values are extracted from the impedance measurement of a real device. In the end, the impedance matching is experimentally tested on this same device and compared to the simulation. A maximum 4,5 mW power is transferred to an optimal load for an input ultrasound pressure of 90 kPa. • An impedance measurement of a real device enables the computation of a precise simulation model. • Both active and passive electronic interfaces can transfer the maximum energy to the load. • A 4.5 mW power is transferred to a DC load with only a matching inductor a diode bridge and a 90 kPa incident pressure.

Sensors and Actuators A PhysicalVol. 379
Université de Tours (FR), Centre National de la Recherche Scientifique (FR)
Agence Nationale de la Recherche, Conseil Régional du Centre-Val de Loire
Affordable and clean energy
Openalex Percentile: Top 36%
Innovative Energy Harvesting Technologies
0.64
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.