Assessment of Angular and Straight Linear Rowing Ergometers at Different Intensities of Exercise

We aimed to conduct a biophysical comparison of angular (Biorower) and linear (Concept2) rowing ergometers across a wide spectrum of exercise intensities. Sixteen (eleven male) skilled rowers, aged 29.8 ± 8.6 and 23.6 ± 1.5 years, with international competitive experience, performed 7 × 3 min bouts with 30 W increments and 60 s intervals, plus 1 min of all-out rowing on both machines with 48 h in between. The ventilatory and kinematical variables were measured breath-by-breath using a telemetric portable gas analyzer and determined using a full-body markerless system, respectively. Similar values of oxygen uptake were observed between ergometers across all intensity domains (e.g., 60.36 ± 8.40 vs. 58.14 ± 7.55 mL/min/kg for the Biorower and Concept2 at severe intensity). The rowing rate was higher on the Biorower vs. Concept2 at heavy and severe intensities (27.88 ± 3.22 vs. 25.69 ± 1.99 and 30.63 ± 3.18 vs. 28.94 ± 2.29). Other differences in kinematics were observed across all intensity domains, particularly in the thorax angle at the finish (e.g., 19.44 ± 4.49 vs. 27.51 ± 7.59° for the Biorower compared to Concep2 at heavy intensity), likely due to closer alignment of the Biorower with an on-water rowing technique. The overall perceived effort was lower on the Biorower when compared to the Concept2 (14.38 ± 1.76 vs. 15.88 ± 1.88). Rowers presented similar cardiorespiratory function on both rowing ergometers, while important biomechanical differences were observed, possibly due to the Biorower's closer alignment with an on-water rowing technique.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-08-31
DOI
https://doi.org/10.3390/s24175686
Citations
6
Primary Topic
Sports Performance and Training
Type
article
Field-Weighted Citation Impact
2.87

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of Angular and Straight Linear Rowing Ergometers at Different Intensities of Exercise

Filipa Cardoso, João Paulo Vilas‐Boas, Pedro Fonseca, Ricardo Cardoso et al.
6 citations
Sensors
Sports Performance and Training
2.87
article

Assessment of Angular and Straight Linear Rowing Ergometers at Different Intensities of Exercise

Filipa Cardoso, João Paulo Vilas‐Boas, Pedro Fonseca, Ricardo Cardoso, Beatriz Branquinho Gomes, J. Arturo Abraldes, Manoel J. Rios, Ricardo J. Fernandes, Joana Leão
article en
6 citations

Abstract

We aimed to conduct a biophysical comparison of angular (Biorower) and linear (Concept2) rowing ergometers across a wide spectrum of exercise intensities. Sixteen (eleven male) skilled rowers, aged 29.8 ± 8.6 and 23.6 ± 1.5 years, with international competitive experience, performed 7 × 3 min bouts with 30 W increments and 60 s intervals, plus 1 min of all-out rowing on both machines with 48 h in between. The ventilatory and kinematical variables were measured breath-by-breath using a telemetric portable gas analyzer and determined using a full-body markerless system, respectively. Similar values of oxygen uptake were observed between ergometers across all intensity domains (e.g., 60.36 ± 8.40 vs. 58.14 ± 7.55 mL/min/kg for the Biorower and Concept2 at severe intensity). The rowing rate was higher on the Biorower vs. Concept2 at heavy and severe intensities (27.88 ± 3.22 vs. 25.69 ± 1.99 and 30.63 ± 3.18 vs. 28.94 ± 2.29). Other differences in kinematics were observed across all intensity domains, particularly in the thorax angle at the finish (e.g., 19.44 ± 4.49 vs. 27.51 ± 7.59° for the Biorower compared to Concep2 at heavy intensity), likely due to closer alignment of the Biorower with an on-water rowing technique. The overall perceived effort was lower on the Biorower when compared to the Concept2 (14.38 ± 1.76 vs. 15.88 ± 1.88). Rowers presented similar cardiorespiratory function on both rowing ergometers, while important biomechanical differences were observed, possibly due to the Biorower's closer alignment with an on-water rowing technique.

SensorsVol. 24(17)
Universidade do Porto (PT), University of Coimbra (PT), Universidad de Murcia (ES)
Fundação para a Ciência e a Tecnologia
Life below water
Openalex Percentile: Top 9%
Sports Performance and Training
2.87
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.