Efficacy of PZT Sensors Network Different Configurations in Damage Detection of Fiber-Reinforced Concrete Prisms under Repeated Loading

Real-time structural health monitoring (SHM) and accurate diagnosis of imminent damage are critical to ensure the structural safety of conventional reinforced concrete (RC) and fiber-reinforced concrete (FRC) structures. Implementations of a piezoelectric lead zirconate titanate (PZT) sensor network in the critical areas of structural members can identify the damage level. This study uses a recently developed PZT-enabled Electro-Mechanical Impedance (EMI)-based, real-time, wireless, and portable SHM and damage detection system in prismatic specimens subjected to flexural repeated loading plain concrete (PC) and FRC. Furthermore, this research examined the efficacy of the proposed SHM methodology for FRC cracking identification of the specimens at various loading levels with different sensor layouts. Additionally, damage quantification using values of statistical damage indices is included. For this reason, the well-known conventional static metric of the Root Mean Square Deviation (RMSD) and the Mean Absolute Percentage Deviation (MAPD) were used and compared. This paper addresses a reliable monitoring experimental methodology in FRC to diagnose damage and predict the forthcoming flexural failure at early damage stages, such as at the onset of cracking. Test results indicated that damage assessment is successfully achieved using RMSD and MAPD indices of a strategically placed network of PZT sensors. Furthermore, the Upper Control Limit (UCL) index was adopted as a threshold for further sifting the scalar damage indices. Additionally, the proposed PZT-enable SHM method for prompt damage level is first established, providing the relationship between the voltage frequency response of the 32 PZT sensors and the crack propagation of the FRC prisms due to the step-by-step increased imposed load. In conclusion, damage diagnosis through continuous monitoring of PZTs responses of FRC due to flexural loading is a quantitative, reliable, and promising application.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-08-30
DOI
https://doi.org/10.3390/s24175660
Citations
22
Primary Topic
Structural Health Monitoring Techniques
Type
article
Field-Weighted Citation Impact
5.74
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Efficacy of PZT Sensors Network Different Configurations in Damage Detection of Fiber-Reinforced Concrete Prisms under Repeated Loading

Maria C. Naoum, George M. Sapidis, Maristella Ε. Voutetaki, Nikos A. Papadopoulos
22 citations
Sensors
Structural Health Monitoring Techniques
5.74
article

Efficacy of PZT Sensors Network Different Configurations in Damage Detection of Fiber-Reinforced Concrete Prisms under Repeated Loading

Maria C. Naoum, George M. Sapidis, Maristella Ε. Voutetaki, Nikos A. Papadopoulos
article en
22 citations

Abstract

Real-time structural health monitoring (SHM) and accurate diagnosis of imminent damage are critical to ensure the structural safety of conventional reinforced concrete (RC) and fiber-reinforced concrete (FRC) structures. Implementations of a piezoelectric lead zirconate titanate (PZT) sensor network in the critical areas of structural members can identify the damage level. This study uses a recently developed PZT-enabled Electro-Mechanical Impedance (EMI)-based, real-time, wireless, and portable SHM and damage detection system in prismatic specimens subjected to flexural repeated loading plain concrete (PC) and FRC. Furthermore, this research examined the efficacy of the proposed SHM methodology for FRC cracking identification of the specimens at various loading levels with different sensor layouts. Additionally, damage quantification using values of statistical damage indices is included. For this reason, the well-known conventional static metric of the Root Mean Square Deviation (RMSD) and the Mean Absolute Percentage Deviation (MAPD) were used and compared. This paper addresses a reliable monitoring experimental methodology in FRC to diagnose damage and predict the forthcoming flexural failure at early damage stages, such as at the onset of cracking. Test results indicated that damage assessment is successfully achieved using RMSD and MAPD indices of a strategically placed network of PZT sensors. Furthermore, the Upper Control Limit (UCL) index was adopted as a threshold for further sifting the scalar damage indices. Additionally, the proposed PZT-enable SHM method for prompt damage level is first established, providing the relationship between the voltage frequency response of the 32 PZT sensors and the crack propagation of the FRC prisms due to the step-by-step increased imposed load. In conclusion, damage diagnosis through continuous monitoring of PZTs responses of FRC due to flexural loading is a quantitative, reliable, and promising application.

SensorsVol. 24(17)
Democritus University of Thrace (GR)
Sustainable cities and communities
Openalex Percentile: Top 3%
Structural Health Monitoring Techniques
5.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.