Effect of vibration on the interface properties of welded steel joints and filled concrete in steel pipes

Concrete-filled steel tubes (CFSTs) have been increasingly utilized in engineering due to their excellent mechanical properties. Ensuring a solid bond between a steel tube and concrete is essential for optimizing their synergistic effect. This study introduces an internally welded steel bar structure within the inner wall of a steel tube to enhance the bond properties at the connection interface. The influence of various configurations of steel bars welded to the inner surface of the tube on the bond strength is investigated considering the impact of vibration on the load-bearing capacity of the component. This study comprises two groups of specimens, one with vibration and one without vibration, for a total of ten specimens. Each group included CFST members with five distinct internal welded steel bar structures. The experimental results, including load-displacement curves and strain data of the steel tube, were used to assess the impact of the internal welded steel bar configurations on the steel-concrete interface. The sliding process is described by correlating test data with curves and observed phenomena. To comprehensively compare the effects of structural dimensions on the bonding and slipping properties of the welded bars, finite element simulations replicating the experimental conditions were carried out using ABAQUS software, and the simulation results agreed with the experimental observations. The study demonstrated that incorporating internal welded steel bars substantially enhances the bond strength of steel pipe-concrete interfaces. While vibration weakens the bond strength in CFST members, internal welded steel bars mitigate this effect. These findings improve the structural performance of CFST structures and their resilience to external vibrations.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-09-02
DOI
https://doi.org/10.1038/s41598-024-68186-0
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of vibration on the interface properties of welded steel joints and filled concrete in steel pipes

Nianchun Deng, Haoxu Li, Xiuning Peng, Guohua Lv et al.
Scientific Reports
Structural Load-Bearing Analysis
article

Effect of vibration on the interface properties of welded steel joints and filled concrete in steel pipes

Nianchun Deng, Haoxu Li, Xiuning Peng, Guohua Lv, Jingyao Ni, Zhaotao Chen
article en

Abstract

Concrete-filled steel tubes (CFSTs) have been increasingly utilized in engineering due to their excellent mechanical properties. Ensuring a solid bond between a steel tube and concrete is essential for optimizing their synergistic effect. This study introduces an internally welded steel bar structure within the inner wall of a steel tube to enhance the bond properties at the connection interface. The influence of various configurations of steel bars welded to the inner surface of the tube on the bond strength is investigated considering the impact of vibration on the load-bearing capacity of the component. This study comprises two groups of specimens, one with vibration and one without vibration, for a total of ten specimens. Each group included CFST members with five distinct internal welded steel bar structures. The experimental results, including load-displacement curves and strain data of the steel tube, were used to assess the impact of the internal welded steel bar configurations on the steel-concrete interface. The sliding process is described by correlating test data with curves and observed phenomena. To comprehensively compare the effects of structural dimensions on the bonding and slipping properties of the welded bars, finite element simulations replicating the experimental conditions were carried out using ABAQUS software, and the simulation results agreed with the experimental observations. The study demonstrated that incorporating internal welded steel bars substantially enhances the bond strength of steel pipe-concrete interfaces. While vibration weakens the bond strength in CFST members, internal welded steel bars mitigate this effect. These findings improve the structural performance of CFST structures and their resilience to external vibrations.

Scientific ReportsVol. 14(1)
Guangxi University (CN)
National Natural Science Foundation of China
Sustainable cities and communities
Openalex Percentile: Top 83%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.