Tough, Slippery, and Low-Permeability Multilayer Hydrogels Modified by Anisotropic Fiber Membrane for Soft Tissue Replacement

Hydrogels with sustained lubrication, high load-bearing capacity, and wear resistance are essential for applications in soft tissue replacements and soft material devices. Traditional tough or lubricious hydrogels fail to balance the lubrication and load-bearing functions. Inspired by the gradient-ordered multilayer structures of natural tissues (such as cartilage and ligaments), a tough, smooth, low-permeability, and low-friction anisotropic layered electrospun fiber membrane-reinforced hydrogel was developed using electrospinning and annealing recrystallization. This hydrogel features a stratified porous network structure of varying sizes with tightly bonded interfaces, achieving an interfacial bonding toughness of 1.6 × 10<sup>3</sup> J/m<sup>2</sup>. The anisotropic fiber membranes, mimicking the orderly fiber structures within soft tissues, significantly enhance the mechanical properties of the hydrogel with a fracture strength of 20.95 MPa, a Young's modulus of 29.64 MPa, and a tear toughness of 37.94 kJ/m<sup>2</sup> and reduce its permeability coefficient (6.1 × 10<sup>-17</sup> m<sup>4</sup> N<sup>-1</sup> s<sup>-1</sup>). Meanwhile, the hydrogel demonstrates excellent solid-liquid phase load-bearing characteristics, which can markedly improve the tribological performance. Under a contact load of 4.1 MPa, the anisotropic fiber membrane-reinforced hydrogel achieves a friction coefficient of 0.036, a 219% reduction compared with pure hydrogels. Thus, the superior load-bearing and lubricating properties of this layered hydrogel underscore its potential applications in soft tissue replacements, medical implants, and other biomedical devices.

Authors

Institutions

Publication Details

Journal
ACS Applied Materials & Interfaces
Published
2024-09-02
DOI
https://doi.org/10.1021/acsami.4c11080
Citations
13
Primary Topic
Electrospun Nanofibers in Biomedical Applications
Type
article
Field-Weighted Citation Impact
2.25

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Tough, Slippery, and Low-Permeability Multilayer Hydrogels Modified by Anisotropic Fiber Membrane for Soft Tissue Replacement

Cunao Feng, Dekun Zhang, Qin Chen, Kai Chen et al.
13 citations
ACS Applied Materials & Interfaces
Electrospun Nanofibers in Biomedical Applications
2.25
article

Tough, Slippery, and Low-Permeability Multilayer Hydrogels Modified by Anisotropic Fiber Membrane for Soft Tissue Replacement

Cunao Feng, Dekun Zhang, Qin Chen, Kai Chen, Haiyan Feng, Xiaowei Li, Xinyue Zhang, Shirong Ge
article en
13 citations

Abstract

Hydrogels with sustained lubrication, high load-bearing capacity, and wear resistance are essential for applications in soft tissue replacements and soft material devices. Traditional tough or lubricious hydrogels fail to balance the lubrication and load-bearing functions. Inspired by the gradient-ordered multilayer structures of natural tissues (such as cartilage and ligaments), a tough, smooth, low-permeability, and low-friction anisotropic layered electrospun fiber membrane-reinforced hydrogel was developed using electrospinning and annealing recrystallization. This hydrogel features a stratified porous network structure of varying sizes with tightly bonded interfaces, achieving an interfacial bonding toughness of 1.6 × 10<sup>3</sup> J/m<sup>2</sup>. The anisotropic fiber membranes, mimicking the orderly fiber structures within soft tissues, significantly enhance the mechanical properties of the hydrogel with a fracture strength of 20.95 MPa, a Young's modulus of 29.64 MPa, and a tear toughness of 37.94 kJ/m<sup>2</sup> and reduce its permeability coefficient (6.1 × 10<sup>-17</sup> m<sup>4</sup> N<sup>-1</sup> s<sup>-1</sup>). Meanwhile, the hydrogel demonstrates excellent solid-liquid phase load-bearing characteristics, which can markedly improve the tribological performance. Under a contact load of 4.1 MPa, the anisotropic fiber membrane-reinforced hydrogel achieves a friction coefficient of 0.036, a 219% reduction compared with pure hydrogels. Thus, the superior load-bearing and lubricating properties of this layered hydrogel underscore its potential applications in soft tissue replacements, medical implants, and other biomedical devices.

ACS Applied Materials & InterfacesVol. 16(36)
China University of Mining and Technology (CN)
National Natural Science Foundation of China, State Key Laboratory of Solid Lubrication
Openalex Percentile: Top 12%
Electrospun Nanofibers in Biomedical Applications
2.25
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.