Comparison of seismic assessment guidelines using a case study reinforced concrete wall building

There are several seismic assessment standards and guidelines available around the world that can be used to identify vulnerable buildings. The assessment procedures and criteria in these documents are different, and thus, the assessment outcomes for a particular building, if assessed using different standards, can also be different. In this study, provisions of the linear static and non-linear static analysis procedures of three prominent seismic assessment documents, the American Society of Civil Engineers /Structural Engineers Institute standard ASCE 41 (2017) [1], the New Zealand Seismic Assessment Guidelines (2017) [2], and the European Standard EN 1998-3 (2005) [3] (also known as Eurocode 8 Part-3 or EC8-3) are discussed and compared, highlighting some of their similarities and differences. A reinforced concrete (RC) wall building used in FEMA P-2006 (2018) [4] for demonstration of ASCE 41 provisions is taken as the case study building for comparison of the assessment provisions. The linear and non-linear static analysis procedures specified in the three documents are applied to the case study building and the assessment outcomes are compared. The assessment results are found to vary across the analysis methods and guidelines. However, the critical governing vulnerability for the building is found to be the same. It is observed that with the simplifying modelling assumptions, coupled with the inherent conservatism in the assessment using linear static analysis, a more conservative outcome is obtained using the linear static methods as compared to the non-linear static methods. Overall, EC8-3 provisions are found to be the most conservative of all three guidelines considered for the assessment of the example building.

Authors

Institutions

Publication Details

Journal
Bulletin of the New Zealand Society for Earthquake Engineering
Published
2024-09-01
DOI
https://doi.org/10.5459/bnzsee.1672
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of seismic assessment guidelines using a case study reinforced concrete wall building

Faraz Zaidi, Max Stephens, Ken Elwood
Bulletin of the New Zealand Society for Earthquake Engineering
Seismic Performance and Analysis
article

Comparison of seismic assessment guidelines using a case study reinforced concrete wall building

Faraz Zaidi, Max Stephens, Ken Elwood
article en

Abstract

There are several seismic assessment standards and guidelines available around the world that can be used to identify vulnerable buildings. The assessment procedures and criteria in these documents are different, and thus, the assessment outcomes for a particular building, if assessed using different standards, can also be different. In this study, provisions of the linear static and non-linear static analysis procedures of three prominent seismic assessment documents, the American Society of Civil Engineers /Structural Engineers Institute standard ASCE 41 (2017) [1], the New Zealand Seismic Assessment Guidelines (2017) [2], and the European Standard EN 1998-3 (2005) [3] (also known as Eurocode 8 Part-3 or EC8-3) are discussed and compared, highlighting some of their similarities and differences. A reinforced concrete (RC) wall building used in FEMA P-2006 (2018) [4] for demonstration of ASCE 41 provisions is taken as the case study building for comparison of the assessment provisions. The linear and non-linear static analysis procedures specified in the three documents are applied to the case study building and the assessment outcomes are compared. The assessment results are found to vary across the analysis methods and guidelines. However, the critical governing vulnerability for the building is found to be the same. It is observed that with the simplifying modelling assumptions, coupled with the inherent conservatism in the assessment using linear static analysis, a more conservative outcome is obtained using the linear static methods as compared to the non-linear static methods. Overall, EC8-3 provisions are found to be the most conservative of all three guidelines considered for the assessment of the example building.

Bulletin of the New Zealand Society for Earthquake EngineeringVol. 57(3)
University of Auckland (NZ)
Sustainable cities and communities
Openalex Percentile: Top 83%
Seismic Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparison of seismic assessment guidelines using a case study reinforced concrete wall building — Faraz Zaidi, Max Stephens, et al. · Bulletin of the New Zealand Society for Earthquake Engineering (2024) | TGRS Research Map | TGRS