Exploring aortic morphology and determining variable-distance insertion lengths for fluoroscopy-free resuscitative endovascular balloon occlusion of the aorta (REBOA)

This is the first study to compare aortic morphology and intravascular distances between combined sex and age-based subgroups. As zone III length was consistent, length variability and elongation seem to mainly originate in the iliofemoral trajectory and zone II. The optimal zone I catheter insertion length would be 430 mm. Optimal zone III catheter insertion ranged between 234 and 264 mm. These standardized variable-distance insertion lengths could facilitate safer fluoroscopy-free REBOA in austere, pre-hospital settings.

Authors

Institutions

Publication Details

Journal
World Journal of Emergency Surgery
Published
2024-08-31
DOI
https://doi.org/10.1186/s13017-024-00557-4
Citations
5
Primary Topic
Trauma and Emergency Care Studies
Type
article
Field-Weighted Citation Impact
3.45

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exploring aortic morphology and determining variable-distance insertion lengths for fluoroscopy-free resuscitative endovascular balloon occlusion of the aorta (REBOA)

Jan C. van de Voort, Boudewijn L.S. Borger van der Burg, Rigo Hoencamp, Barbara B. Verbeek
5 citations
World Journal of Emergency Surgery
Trauma and Emergency Care Studies
3.45
article

Exploring aortic morphology and determining variable-distance insertion lengths for fluoroscopy-free resuscitative endovascular balloon occlusion of the aorta (REBOA)

Jan C. van de Voort, Boudewijn L.S. Borger van der Burg, Rigo Hoencamp, Barbara B. Verbeek
article en
5 citations

Abstract

This is the first study to compare aortic morphology and intravascular distances between combined sex and age-based subgroups. As zone III length was consistent, length variability and elongation seem to mainly originate in the iliofemoral trajectory and zone II. The optimal zone I catheter insertion length would be 430 mm. Optimal zone III catheter insertion ranged between 234 and 264 mm. These standardized variable-distance insertion lengths could facilitate safer fluoroscopy-free REBOA in austere, pre-hospital settings.

World Journal of Emergency SurgeryVol. 19(1)
Leiden University Medical Center (NL), Erasmus MC (NL), Ministry of Defence (NL), Alrijne Ziekenhuis (NL), Erasmus University Rotterdam (NL)
Ministry of Defense
Good health and well-being
Openalex Percentile: Top 8%
Trauma and Emergency Care Studies
3.45
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Exploring aortic morphology and determining variable-distance insertion lengths for fluoroscopy-free resuscitative endovascular balloon occlusion of the aorta (REBOA) — Jan C. van de Voort, Boudewijn L.S. Borger van der Burg, et al. · World Journal of Emergency Surgery (2024) | TGRS Research Map | TGRS