VOLUME REPLENISHMENT BY BOLUS LIQUID INFUSION: WHATROLE IN THE ACUTE MANAGEMENT OF INTRADIALYTIC HYPOTENSION (IDH)?

Introduction: Intradialytic hypotension (IDH) is a common complication associatedwith high morbidity and mortality in hemodialysis patients. Its management isprimarilypreventive, but if itoccurs, itrequires urgent measuresincluding volume infusion of solute to restore volemia. The objective of ourworkis to evaluate the role of bolus liquid infusion for the acute management of IDH. Materials and Methods: This is a retrospectivestudyconductedfromJanuary 2017 to December 2021 at the hemodialysis center of the militaryhospital in Agadir involving 90 chronichemodialysis patients. Volume replenishment to treat IDH wascarried out by infusing an online bolus liquid. Results and Discussion: Weanalyzed 30,689 sessions. IDH with or withoutsymptomswasfoundin 19.6% of cases. 14% of sessions with IDH required bolus infusion (27% of total sessions) with an average volume injected of 26315 ± 1622 ml. Factorsassociatedwith bolus administration includedadvancedage (643 ± 127 vs. 61.6 ± 12.7 years, P<0.001), femalesex (H/F ratio of 0.5 vs. 1.1, P<0.001), diabetes (47.4% vs. 44%, P<0.001), lowpre-dialyticnatremia (134 ± 14 vs. 136 ± 10 mmol/l, P<0.001), and underestimated dry weight (70.6 ± 12.5 vs. 73 ± 14.2 kg, P<0.001). Sessions with bolus infusion werecharacterized by a low total effective UF volume (2000 ± 870 ml vs. 2285.8 ± 854.8, P<0.001), shorter duration withpremature session disconnection (209 ± 25 min vs. 235 ± 7 min, P=0.02), and loweraveragedialysatetemperature (P<0.001). The final relative blood volume washigher (87 ± 9 vs. 82 ± 9, P<0.001) favoring the risk of overloadassociatedwith bolus infusion. Conclusion: Despiteadvances in hemodialysis, IDH remains a common per-dialytic incident. Our study highlights the importance of close monitoring of hemodynamicparametersduringhemodialysis sessions to prevent IDH, actearly, and avoidliquid bolus administration associatedwith the risk of overload.

Authors

Publication Details

Journal
International Journal of Advanced Research
Published
2024-08-31
DOI
https://doi.org/10.21474/ijar01/19239
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

VOLUME REPLENISHMENT BY BOLUS LIQUID INFUSION: WHATROLE IN THE ACUTE MANAGEMENT OF INTRADIALYTIC HYPOTENSION (IDH)?

Ahmed Alayoud, El Ouazzani Mouad, Jabrane Marouane, El Khand Ali et al.
International Journal of Advanced Research
Hemodynamic Monitoring and Therapy
article

VOLUME REPLENISHMENT BY BOLUS LIQUID INFUSION: WHATROLE IN THE ACUTE MANAGEMENT OF INTRADIALYTIC HYPOTENSION (IDH)?

Ahmed Alayoud, El Ouazzani Mouad, Jabrane Marouane, El Khand Ali, Bouchoual Mohammed, Anibar Sara, Arrayhani Mohammed
article en

Abstract

Introduction: Intradialytic hypotension (IDH) is a common complication associatedwith high morbidity and mortality in hemodialysis patients. Its management isprimarilypreventive, but if itoccurs, itrequires urgent measuresincluding volume infusion of solute to restore volemia. The objective of ourworkis to evaluate the role of bolus liquid infusion for the acute management of IDH. Materials and Methods: This is a retrospectivestudyconductedfromJanuary 2017 to December 2021 at the hemodialysis center of the militaryhospital in Agadir involving 90 chronichemodialysis patients. Volume replenishment to treat IDH wascarried out by infusing an online bolus liquid. Results and Discussion: Weanalyzed 30,689 sessions. IDH with or withoutsymptomswasfoundin 19.6% of cases. 14% of sessions with IDH required bolus infusion (27% of total sessions) with an average volume injected of 26315 ± 1622 ml. Factorsassociatedwith bolus administration includedadvancedage (643 ± 127 vs. 61.6 ± 12.7 years, P<0.001), femalesex (H/F ratio of 0.5 vs. 1.1, P<0.001), diabetes (47.4% vs. 44%, P<0.001), lowpre-dialyticnatremia (134 ± 14 vs. 136 ± 10 mmol/l, P<0.001), and underestimated dry weight (70.6 ± 12.5 vs. 73 ± 14.2 kg, P<0.001). Sessions with bolus infusion werecharacterized by a low total effective UF volume (2000 ± 870 ml vs. 2285.8 ± 854.8, P<0.001), shorter duration withpremature session disconnection (209 ± 25 min vs. 235 ± 7 min, P=0.02), and loweraveragedialysatetemperature (P<0.001). The final relative blood volume washigher (87 ± 9 vs. 82 ± 9, P<0.001) favoring the risk of overloadassociatedwith bolus infusion. Conclusion: Despiteadvances in hemodialysis, IDH remains a common per-dialytic incident. Our study highlights the importance of close monitoring of hemodynamicparametersduringhemodialysis sessions to prevent IDH, actearly, and avoidliquid bolus administration associatedwith the risk of overload.

International Journal of Advanced ResearchVol. 12(08)
Good health and well-being
Openalex Percentile: Top 73%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

VOLUME REPLENISHMENT BY BOLUS LIQUID INFUSION: WHATROLE IN THE ACUTE MANAGEMENT OF INTRADIALYTIC HYPOTENSION (IDH)? — Ahmed Alayoud, El Ouazzani Mouad, et al. · International Journal of Advanced Research (2024) | TGRS Research Map | TGRS