STUDY OF HEAT CONDUCTION ON THERMO-ACTIVE BUILDING SYSTEM WITH THE FLOOR-MOUNTED WATER PANEL

In recent years, Thermally Activated Building Systems (TABS), which utilize the thermal mass of building structures, are gaining attention. Traditional TABS uses piping embedded in the concrete slab. That makes difficulty to maintain building for long term due to the inaccessible piping, and refurbishment possibly causes a damage on the structure. To solve this problem, we have developed TABS using floor-mounted cold and hot water panels. In this study, heat conduction around the panels is represented in detail based on the measurements. We confirmed that presented TABS system has shown similar figure to reference data of traditional TABS method.

Authors

Institutions

Publication Details

Journal
Journal of Environmental Engineering (Transactions of AIJ)
Published
2024-08-31
DOI
https://doi.org/10.3130/aije.89.564
Citations
1
Primary Topic
Energy, Environment, Agriculture Analysis
Type
article
Field-Weighted Citation Impact
0.10
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

STUDY OF HEAT CONDUCTION ON THERMO-ACTIVE BUILDING SYSTEM WITH THE FLOOR-MOUNTED WATER PANEL

Kinuko KUWAYAMA, Kotaro MAKINO
1 citations
Journal of Environmental Engineering (Transactions of AIJ)
Energy, Environment, Agriculture Analysis
0.10
article

STUDY OF HEAT CONDUCTION ON THERMO-ACTIVE BUILDING SYSTEM WITH THE FLOOR-MOUNTED WATER PANEL

Kinuko KUWAYAMA, Kotaro MAKINO
article en
1 citations

Abstract

In recent years, Thermally Activated Building Systems (TABS), which utilize the thermal mass of building structures, are gaining attention. Traditional TABS uses piping embedded in the concrete slab. That makes difficulty to maintain building for long term due to the inaccessible piping, and refurbishment possibly causes a damage on the structure. To solve this problem, we have developed TABS using floor-mounted cold and hot water panels. In this study, heat conduction around the panels is represented in detail based on the measurements. We confirmed that presented TABS system has shown similar figure to reference data of traditional TABS method.

Journal of Environmental Engineering (Transactions of AIJ)Vol. 89(823)
Kogakuin University (JP), Takenaka (Japan) (JP)
Openalex Percentile: Top 65%
Energy, Environment, Agriculture Analysis
0.10
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.