Assessment of Indoor Air Chemical Pollutants at Faculty of Health Sciences Administrative Offices Universiti Kebangsaan Malaysia, Kuala Lumpur Campus

The 2010 guidelines for indoor air quality (ICOP IAQ 2010) provide a framework for evaluating and sustaining healthy indoor environments in enclosed spaces, promoting a safer and more comfortable atmosphere for occupants. Chemical pollutants in indoor air measured in this study are particulate matter (PM10), carbon monoxide (CO), carbon dioxide (CO2), total volatile organic compounds (TVOC), formaldehyde (CH2O) and ozone (O3). A total of six sampling locations were selected, namely P1 (ReaCH), P2 (CORE), P3 (H-Care), P4 (iCaRehab & CODTIS), P5 (PD) and P6 (PTD). The results of the study found that all chemical parameters measured were found to comply with the limits allowed by ICOP IAQ 2010 except for ozone (O3) readings. The average range of carbon monoxide (CO) readings was recorded to be (0.0+0.0 ppm - 0.6+0.01 ppm) and still below the ICOP IAQ 2010 limit (10 ppm). CO2 readings ranged between (582+104 ppm - 847+67 ppm) with all readings at sampling locations complying with ICOP IAQ 2010 limits (1000 ppm). The average value for PM10 readings ranges between (0.01+0.01 ppm - 0.03+0.01 ppm) and all readings are below the ICOP IAQ 2010 limit (0.15 ppm). TVOC readings range between (0.0 + 0.0 ppm - 1.8 + 0.01 ppm) and all readings are below the ICOP IAQ 2010 limit (3 ppm). The average value for formaldehyde concentration between the reading range (0.00 + 0.00 ppm – 0.96 + 0.01 ppm) and it complies with the ICOP IAQ 2010 limit (0.10 ppm). The average O3 concentration exceeds the ICOP IAQ 2010 standard (i.e., 0.05 ppm) in the range of 0.00 + 0.00 – 0.06 + 0.01 ppm. Overall, the indoor air quality in all UKM Faculty of Health Sciences administrative offices is in good condition. However, monitoring indoor air quality periodically needs to be done to ensure that the occupants are always healthy and in a comfortable condition as well as being able to increase work productivity.

Authors

Institutions

Publication Details

Journal
Oriental Journal Of Chemistry
Published
2024-08-30
DOI
https://doi.org/10.13005/ojc/400401
Primary Topic
Air Quality and Health Impacts
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of Indoor Air Chemical Pollutants at Faculty of Health Sciences Administrative Offices Universiti Kebangsaan Malaysia, Kuala Lumpur Campus

Atiah Ayunni Abdul Ghani, Nur Faizah Abu Bakar, S Rahman, M R Abdullah et al.
Oriental Journal Of Chemistry
Air Quality and Health Impacts
article

Assessment of Indoor Air Chemical Pollutants at Faculty of Health Sciences Administrative Offices Universiti Kebangsaan Malaysia, Kuala Lumpur Campus

Atiah Ayunni Abdul Ghani, Nur Faizah Abu Bakar, S Rahman, M R Abdullah, M. G. Aman, Normah Awang, Noraizah Muhd. Nor
article en

Abstract

The 2010 guidelines for indoor air quality (ICOP IAQ 2010) provide a framework for evaluating and sustaining healthy indoor environments in enclosed spaces, promoting a safer and more comfortable atmosphere for occupants. Chemical pollutants in indoor air measured in this study are particulate matter (PM10), carbon monoxide (CO), carbon dioxide (CO2), total volatile organic compounds (TVOC), formaldehyde (CH2O) and ozone (O3). A total of six sampling locations were selected, namely P1 (ReaCH), P2 (CORE), P3 (H-Care), P4 (iCaRehab & CODTIS), P5 (PD) and P6 (PTD). The results of the study found that all chemical parameters measured were found to comply with the limits allowed by ICOP IAQ 2010 except for ozone (O3) readings. The average range of carbon monoxide (CO) readings was recorded to be (0.0+0.0 ppm - 0.6+0.01 ppm) and still below the ICOP IAQ 2010 limit (10 ppm). CO2 readings ranged between (582+104 ppm - 847+67 ppm) with all readings at sampling locations complying with ICOP IAQ 2010 limits (1000 ppm). The average value for PM10 readings ranges between (0.01+0.01 ppm - 0.03+0.01 ppm) and all readings are below the ICOP IAQ 2010 limit (0.15 ppm). TVOC readings range between (0.0 + 0.0 ppm - 1.8 + 0.01 ppm) and all readings are below the ICOP IAQ 2010 limit (3 ppm). The average value for formaldehyde concentration between the reading range (0.00 + 0.00 ppm – 0.96 + 0.01 ppm) and it complies with the ICOP IAQ 2010 limit (0.10 ppm). The average O3 concentration exceeds the ICOP IAQ 2010 standard (i.e., 0.05 ppm) in the range of 0.00 + 0.00 – 0.06 + 0.01 ppm. Overall, the indoor air quality in all UKM Faculty of Health Sciences administrative offices is in good condition. However, monitoring indoor air quality periodically needs to be done to ensure that the occupants are always healthy and in a comfortable condition as well as being able to increase work productivity.

Oriental Journal Of ChemistryVol. 40(4)
National University of Malaysia (MY)
Openalex Percentile: Top 80%
Air Quality and Health Impacts
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.