Advanced Exergy Analysis of GT-sCO2 Combined Cycle

Abstract The use of the supercritical carbon dioxide Brayton cycle (SCBC) for waste heat recovery from the gas turbine cycle (GTC) can enhance system performance and reduce CO2 emissions. To analyze the possibility of component optimization and the characteristics of the exergy destruction, a model of a gas turbine-supercritical carbon dioxide (GT-sCO2) combined system with a triple cascade layout has been established, and the exergy destruction of the GT-sCO2 combined system has been analyzed for the first time using an advanced exergy analysis based on a conventional exergy analysis, which further classified the exergy destruction into endogenous, exogenous, avoidable, and unavoidable, and pointed out the direction for the optimization of the new system. The results reveal that the GTC subsystem has larger destruction than the SCBC subsystem. The endogenous exergy destruction ratio of the GT-sCO2 combined cycle is 88.86%, while the endogenous avoidable part is 20.94%. The combustion chamber has the largest endogenous avoidable exergy destruction in the GTC subsystem (51.42 MW), while the sCO2 compressor has the largest endogenous avoidable exergy destruction in the SCBC subsystem (1.89 MW). Depending on the endogenous avoidable exergy destruction, the order of optimization of components is: combustion chamber, gas turbine, air compressor, sCO2 compressor, high-temperature sCO2 turbine, cooler, high-temperature recuperator, low-temperature sCO2 turbine, and low-temperature recuperator, and the corresponding component improvement suggestions are made to aid in subsequent optimization efforts.

Authors

Institutions

Publication Details

Journal
Journal of Thermal Science and Engineering Applications
Published
2024-08-30
DOI
https://doi.org/10.1115/1.4066405
Citations
2
Primary Topic
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.43
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Advanced Exergy Analysis of GT-sCO2 Combined Cycle

Yuxuan Hu, Du Wang, Zhigang Wang, Xin Ren et al.
2 citations
Journal of Thermal Science and Engineering Applications
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
0.43
article

Advanced Exergy Analysis of GT-sCO2 Combined Cycle

Yuxuan Hu, Du Wang, Zhigang Wang, Xin Ren, Mujie Xue
article en
2 citations

Abstract

Abstract The use of the supercritical carbon dioxide Brayton cycle (SCBC) for waste heat recovery from the gas turbine cycle (GTC) can enhance system performance and reduce CO2 emissions. To analyze the possibility of component optimization and the characteristics of the exergy destruction, a model of a gas turbine-supercritical carbon dioxide (GT-sCO2) combined system with a triple cascade layout has been established, and the exergy destruction of the GT-sCO2 combined system has been analyzed for the first time using an advanced exergy analysis based on a conventional exergy analysis, which further classified the exergy destruction into endogenous, exogenous, avoidable, and unavoidable, and pointed out the direction for the optimization of the new system. The results reveal that the GTC subsystem has larger destruction than the SCBC subsystem. The endogenous exergy destruction ratio of the GT-sCO2 combined cycle is 88.86%, while the endogenous avoidable part is 20.94%. The combustion chamber has the largest endogenous avoidable exergy destruction in the GTC subsystem (51.42 MW), while the sCO2 compressor has the largest endogenous avoidable exergy destruction in the SCBC subsystem (1.89 MW). Depending on the endogenous avoidable exergy destruction, the order of optimization of components is: combustion chamber, gas turbine, air compressor, sCO2 compressor, high-temperature sCO2 turbine, cooler, high-temperature recuperator, low-temperature sCO2 turbine, and low-temperature recuperator, and the corresponding component improvement suggestions are made to aid in subsequent optimization efforts.

Journal of Thermal Science and Engineering ApplicationsVol. 16(12)
Shanghai University of Electric Power (CN), China Huadian Corporation (China) (CN), Pudong New Area People's Hospital (CN)
Openalex Percentile: Top 43%
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
0.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Advanced Exergy Analysis of GT-sCO2 Combined Cycle — Yuxuan Hu, Du Wang, et al. · Journal of Thermal Science and Engineering Applications (2024) | TGRS Research Map | TGRS