Impact of Turbine-Strut Clocking and Turbine Outlet Swirl on the Heat Transfer and Film Cooling in an Aggressive Turbine Center Frame

Abstract This study focuses on the thermal impact of the clocking position of the high-pressure turbine (HPT) vanes with respect to the turbine center frame (TCF) struts and the thermal impact of the HPT outlet swirl. The TCF is a stationary duct equipped with nonturning airfoils (struts), and it connects the HPT to the low-pressure turbine (LPT). The heat transfer coefficient and the purge film cooling effectiveness are measured in an aggressive TCF for two turbine-strut clocking positions and two HPT outlet swirl levels. The measurements are carried out in a product-representative 1.5-stage HPT-TCF-LPT vane configuration under Mach similarity. The unshrouded HPT is fully purged with four individually adjustable purge flows, and the film cooling effectiveness of these purge flows in the downstream TCF is investigated. The biggest influence of turbine-strut clocking was found for the heat transfer coefficient on the struts. By clocking the HPT vanes by half a vane pitch from the thermally least to the most favorable position, a significant heat transfer reduction was achieved for both the nominal and the increased HPT outlet swirl. Increasing the HPT outlet swirl increased the flow incidence of the TCF struts and affected the heat transfer along the struts significantly. On the TCF hub, the averaged heat transfer coefficient and the averaged purge film cooling effectiveness responded relatively robustly to all imposed operating point deviations with differences of less than 2%. However, the effects on the local heat transfer and film cooling distributions on the hub were more significant.

Authors

Institutions

Publication Details

Journal
Journal of Turbomachinery
Published
2024-08-30
DOI
https://doi.org/10.1115/1.4066408
Primary Topic
Turbomachinery Performance and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Turbine-Strut Clocking and Turbine Outlet Swirl on the Heat Transfer and Film Cooling in an Aggressive Turbine Center Frame

Bastian Patzer, Patrick R. Jagerhofer, Tobias Glasenapp, Emil Göttlich
Journal of Turbomachinery
Turbomachinery Performance and Optimization
article

Impact of Turbine-Strut Clocking and Turbine Outlet Swirl on the Heat Transfer and Film Cooling in an Aggressive Turbine Center Frame

Bastian Patzer, Patrick R. Jagerhofer, Tobias Glasenapp, Emil Göttlich
article en

Abstract

Abstract This study focuses on the thermal impact of the clocking position of the high-pressure turbine (HPT) vanes with respect to the turbine center frame (TCF) struts and the thermal impact of the HPT outlet swirl. The TCF is a stationary duct equipped with nonturning airfoils (struts), and it connects the HPT to the low-pressure turbine (LPT). The heat transfer coefficient and the purge film cooling effectiveness are measured in an aggressive TCF for two turbine-strut clocking positions and two HPT outlet swirl levels. The measurements are carried out in a product-representative 1.5-stage HPT-TCF-LPT vane configuration under Mach similarity. The unshrouded HPT is fully purged with four individually adjustable purge flows, and the film cooling effectiveness of these purge flows in the downstream TCF is investigated. The biggest influence of turbine-strut clocking was found for the heat transfer coefficient on the struts. By clocking the HPT vanes by half a vane pitch from the thermally least to the most favorable position, a significant heat transfer reduction was achieved for both the nominal and the increased HPT outlet swirl. Increasing the HPT outlet swirl increased the flow incidence of the TCF struts and affected the heat transfer along the struts significantly. On the TCF hub, the averaged heat transfer coefficient and the averaged purge film cooling effectiveness responded relatively robustly to all imposed operating point deviations with differences of less than 2%. However, the effects on the local heat transfer and film cooling distributions on the hub were more significant.

Journal of TurbomachineryVol. 147(2)
Graz University of Technology (AT), MTU Aero Engines (Germany) (DE)
Openalex Percentile: Top 78%
Turbomachinery Performance and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Impact of Turbine-Strut Clocking and Turbine Outlet Swirl on the Heat Transfer and Film Cooling in an Aggressive Turbine Center Frame — Bastian Patzer, Patrick R. Jagerhofer, et al. · Journal of Turbomachinery (2024) | TGRS Research Map | TGRS