Aortic valve replacement with the MedInzh-ST full-flow mechanical implant and modern bicuspid model: comparison of short-term results

Introduction: Mechanical heart valves prostheses have certain disadvantages related to impeding blood flow due to their shape and the design principle of the locking elements. The design of the new model of mechanical prostheses is based on the principle of full flow, which enables to increase the effective area of the valve opening and retain the identical dimensions of the implant. The results of using this type of prosthesis have not been sufficiently studied. Objective: The study aimed to compare the short-term results of aortic valve replacement with the mechanical full-flow prosthesis and with the standard mechanical prosthesis. Methods: The retrospective study included 246 patients who underwent aortic valve replacement with mechanical prosthesis over the period from 2015 to 2021. The MedInzh-2 classical bicuspid valve was implanted in 134 patients, and the new full-flow prosthesis was used in 112 patients. A pseudorandomization procedure (Propensity score matching) was performed to equalize the groups. The level of the transprosthetic gradient was used as the primary endpoint. Results: Propensity score matching resulted into forming two groups of 90 patients each. Hospital mortality in the MedInzh-ST group and the MedInzh-2 group amounted to 2.2% and 6.7%, respectively (Р = 0.178). In the early postoperative period, no differences in the processes of left ventricular cavity remodeling were found between the groups. In the MedInzh-ST full-flow prosthesis group, significantly lower values of transprosthetic gradients were revealed (mean gradients 12.6 versus 16.1 mm Hg, P < 0.001). The effective prosthetic orifice area was statistically higher in the full-flow implant group (2.04 versus 1.89 cm2, P < 0.001). Conclusion: Application of the MedInzh-ST mechanical valve proved to be safe at surgical correction of aortic valve diseases. The prosthesis was hemodynamically effective that was confirmed by a significantly lower level of transprosthetic gradient and a larger effective valve orifice area in comparison to the standard bicuspid mechanical prosthesis. Received 4 April 2024. Revised 18 August 2024. Accepted 20 August 2024. FundingThe study was supported by the Grant of the Russian Science Foundation No. 23-15-00434. Conflict of interestThe authors declare no conflict of interest. Contribution of the authorsThe authors contributed equally to this article.

Authors

Institutions

Publication Details

Journal
Patologiya krovoobrashcheniya i kardiokhirurgiya
Published
2024-08-29
DOI
https://doi.org/10.21688/1681-3472-2024-2-62-72
Citations
1
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Aortic valve replacement with the MedInzh-ST full-flow mechanical implant and modern bicuspid model: comparison of short-term results

Alexander Bogachev‐Prokophiev, Ravil Sharifulin, В. Н. Цеханович, Michail Lepilin
1 citations
Patologiya krovoobrashcheniya i kardiokhirurgiya
Cardiac Valve Diseases and Treatments
0.40
article

Aortic valve replacement with the MedInzh-ST full-flow mechanical implant and modern bicuspid model: comparison of short-term results

Alexander Bogachev‐Prokophiev, Ravil Sharifulin, В. Н. Цеханович, Michail Lepilin
article en
1 citations

Abstract

Introduction: Mechanical heart valves prostheses have certain disadvantages related to impeding blood flow due to their shape and the design principle of the locking elements. The design of the new model of mechanical prostheses is based on the principle of full flow, which enables to increase the effective area of the valve opening and retain the identical dimensions of the implant. The results of using this type of prosthesis have not been sufficiently studied. Objective: The study aimed to compare the short-term results of aortic valve replacement with the mechanical full-flow prosthesis and with the standard mechanical prosthesis. Methods: The retrospective study included 246 patients who underwent aortic valve replacement with mechanical prosthesis over the period from 2015 to 2021. The MedInzh-2 classical bicuspid valve was implanted in 134 patients, and the new full-flow prosthesis was used in 112 patients. A pseudorandomization procedure (Propensity score matching) was performed to equalize the groups. The level of the transprosthetic gradient was used as the primary endpoint. Results: Propensity score matching resulted into forming two groups of 90 patients each. Hospital mortality in the MedInzh-ST group and the MedInzh-2 group amounted to 2.2% and 6.7%, respectively (Р = 0.178). In the early postoperative period, no differences in the processes of left ventricular cavity remodeling were found between the groups. In the MedInzh-ST full-flow prosthesis group, significantly lower values of transprosthetic gradients were revealed (mean gradients 12.6 versus 16.1 mm Hg, P < 0.001). The effective prosthetic orifice area was statistically higher in the full-flow implant group (2.04 versus 1.89 cm2, P < 0.001). Conclusion: Application of the MedInzh-ST mechanical valve proved to be safe at surgical correction of aortic valve diseases. The prosthesis was hemodynamically effective that was confirmed by a significantly lower level of transprosthetic gradient and a larger effective valve orifice area in comparison to the standard bicuspid mechanical prosthesis. Received 4 April 2024. Revised 18 August 2024. Accepted 20 August 2024. FundingThe study was supported by the Grant of the Russian Science Foundation No. 23-15-00434. Conflict of interestThe authors declare no conflict of interest. Contribution of the authorsThe authors contributed equally to this article.

Patologiya krovoobrashcheniya i kardiokhirurgiyaVol. 28(2)
Physical Sciences (United States) (US)
Good health and well-being
Openalex Percentile: Top 34%
Cardiac Valve Diseases and Treatments
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.