Highly stable and selective determination of glucose by a modified glassy carbon electrode based on micro-rods [Ni(HL)NCS] complex as a novel modifier

Non-enzymatic glucose sensors have acquired a lot of attention, where the modifier materials perform as an electrocatalyst instead of an enzyme on the surface of electrodes. More active sites, increased synergistic reactions, and expanded contacts between the electrolyte and the catalyst are essential to enhance catalytic performances. Numerous efforts have been made to fabricate novel non-enzymatic glucose sensors with electrode modification strategies. Herein, a non-enzymatic electrochemical glucose sensor was constructed by a modified glassy carbon electrode (GCE) based on micro-rods [Ni(HL)NCS] complex (MR-NiC/GCE) as a novel modifier for the glucose detection. In alkali media, the non-enzymatic glucose sensor showed a linear dynamic range (LDR) of 100-1100 µM with an excellent limit of detection (LOD) of 15.8 μM (S/N= 3). The proposed sensor demonstrated remarkable stability (after recording 50 continuous cycles), good reproducibility, and significant anti-interference performance toward fructose (Fru), ascorbic acid (AA), dopamine (DA), citric acid (CA), uric acid (UA) and sucrose. According to this study, complexes can be an excellent suggestion to fabricate non-enzymatic glucose sensors.

Authors

Institutions

Publication Details

Journal
Journal of Electrochemical Science and Engineering
Published
2024-08-29
DOI
https://doi.org/10.5599/jese.2368
Citations
1
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Highly stable and selective determination of glucose by a modified glassy carbon electrode based on micro-rods [Ni(HL)NCS] complex as a novel modifier

Hamideh Mohammadian-Sarcheshmeh, Mohammad Javad Khatami, Rasoul Vafazadeh, Mohammad Mazloum-Ardakani
1 citations
Journal of Electrochemical Science and Engineering
Electrochemical sensors and biosensors
0.21
article

Highly stable and selective determination of glucose by a modified glassy carbon electrode based on micro-rods [Ni(HL)NCS] complex as a novel modifier

Hamideh Mohammadian-Sarcheshmeh, Mohammad Javad Khatami, Rasoul Vafazadeh, Mohammad Mazloum-Ardakani
article en
1 citations

Abstract

Non-enzymatic glucose sensors have acquired a lot of attention, where the modifier materials perform as an electrocatalyst instead of an enzyme on the surface of electrodes. More active sites, increased synergistic reactions, and expanded contacts between the electrolyte and the catalyst are essential to enhance catalytic performances. Numerous efforts have been made to fabricate novel non-enzymatic glucose sensors with electrode modification strategies. Herein, a non-enzymatic electrochemical glucose sensor was constructed by a modified glassy carbon electrode (GCE) based on micro-rods [Ni(HL)NCS] complex (MR-NiC/GCE) as a novel modifier for the glucose detection. In alkali media, the non-enzymatic glucose sensor showed a linear dynamic range (LDR) of 100-1100 µM with an excellent limit of detection (LOD) of 15.8 μM (S/N= 3). The proposed sensor demonstrated remarkable stability (after recording 50 continuous cycles), good reproducibility, and significant anti-interference performance toward fructose (Fru), ascorbic acid (AA), dopamine (DA), citric acid (CA), uric acid (UA) and sucrose. According to this study, complexes can be an excellent suggestion to fabricate non-enzymatic glucose sensors.

Journal of Electrochemical Science and Engineering
Yazd University (IR)
Yazd University
Openalex Percentile: Top 49%
Electrochemical sensors and biosensors
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Highly stable and selective determination of glucose by a modified glassy carbon electrode based on micro-rods [Ni(HL)NCS] complex as a novel modifier — Hamideh Mohammadian-Sarcheshmeh, Mohammad Javad Khatami, et al. · Journal of Electrochemical Science and Engineering (2024) | TGRS Research Map | TGRS