Accuracy of 128-slice multi-detector computed tomography in the detection of stenosis at different cut-off values in corresponding target areas on conventional angiogram

Background: Coronary artery disease (CAD) is a common medical condition. Over the years, assessment methods for CAD have evolved, with non-invasive techniques gaining prominence. Multi-detector computed tomography (MDCT) coronary angiography has emerged as an alternative to conventional invasive coronary angiography (ICA). This study aimed to evaluate the diagnostic accuracy of 128-slice MDCT in detecting stenosis at various thresholds and compare its efficacy with traditional coronary angiography. Methods: This cross-sectional study was conducted at the radiology and imaging department of combined military hospital (CMH) in Dhaka from August 2021 to July 2022. Forty-three patients were selected through purposive sampling. Computed tomographic angiography was performed using a 128-slice MDCT scanner. Data analysis was conducted using SPSS, with statistical significance set at p<0.05. Sensitivity, specificity, diagnostic accuracy, negative predictive value (NPV), and positive predictive value (PPV) were calculated for each patient and segment. Sensitivity and specificity were assessed for stenosis exceeding 75% and 50%. Result: For diagnosing stenosis less than 50%, the sensitivity, specificity, PPV, NPV, and accuracy were 83.9%, 95.6%, 61.0%, 98.6%, and 94.7%, respectively. For stenosis greater than 50%, they were 84.2%, 99.3%, 86.5%, 99.1%, and 98.5%. For stenosis exceeding 75%, the values were 100.0%, 99.9%, 97.0%, 100.0%, and 99.9%. Conclusions: 128-slice CT provides a reliable non-invasive method to assess hemodynamically significant CAD with high diagnostic accuracy. The study findings suggest that at the artery level, MDCT demonstrates high level of accuracy in identifying significant obstructive CAD.

Authors

Publication Details

Journal
International Surgery Journal
Published
2024-08-29
DOI
https://doi.org/10.18203/2349-2902.isj20242445
Citations
1
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy of 128-slice multi-detector computed tomography in the detection of stenosis at different cut-off values in corresponding target areas on conventional angiogram

Farhana Zaman, M. Javed Mahfuz Khan, Abdulla Al Mahaj Chowdhury
1 citations
International Surgery Journal
Advanced X-ray and CT Imaging
0.18
article

Accuracy of 128-slice multi-detector computed tomography in the detection of stenosis at different cut-off values in corresponding target areas on conventional angiogram

Farhana Zaman, M. Javed Mahfuz Khan, Abdulla Al Mahaj Chowdhury
article en
1 citations

Abstract

Background: Coronary artery disease (CAD) is a common medical condition. Over the years, assessment methods for CAD have evolved, with non-invasive techniques gaining prominence. Multi-detector computed tomography (MDCT) coronary angiography has emerged as an alternative to conventional invasive coronary angiography (ICA). This study aimed to evaluate the diagnostic accuracy of 128-slice MDCT in detecting stenosis at various thresholds and compare its efficacy with traditional coronary angiography. Methods: This cross-sectional study was conducted at the radiology and imaging department of combined military hospital (CMH) in Dhaka from August 2021 to July 2022. Forty-three patients were selected through purposive sampling. Computed tomographic angiography was performed using a 128-slice MDCT scanner. Data analysis was conducted using SPSS, with statistical significance set at p<0.05. Sensitivity, specificity, diagnostic accuracy, negative predictive value (NPV), and positive predictive value (PPV) were calculated for each patient and segment. Sensitivity and specificity were assessed for stenosis exceeding 75% and 50%. Result: For diagnosing stenosis less than 50%, the sensitivity, specificity, PPV, NPV, and accuracy were 83.9%, 95.6%, 61.0%, 98.6%, and 94.7%, respectively. For stenosis greater than 50%, they were 84.2%, 99.3%, 86.5%, 99.1%, and 98.5%. For stenosis exceeding 75%, the values were 100.0%, 99.9%, 97.0%, 100.0%, and 99.9%. Conclusions: 128-slice CT provides a reliable non-invasive method to assess hemodynamically significant CAD with high diagnostic accuracy. The study findings suggest that at the artery level, MDCT demonstrates high level of accuracy in identifying significant obstructive CAD.

International Surgery JournalVol. 11(9)
Good health and well-being
Openalex Percentile: Top 53%
Advanced X-ray and CT Imaging
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Accuracy of 128-slice multi-detector computed tomography in the detection of stenosis at different cut-off values in corresponding target areas on conventional angiogram — Farhana Zaman, M. Javed Mahfuz Khan, et al. · International Surgery Journal (2024) | TGRS Research Map | TGRS