A high-throughput sample preparation approach for the determination of nonsteroidal anti-inflammatory drugs in urine samples through membrane-based microextraction employing a green supramolecular solvent

• Hollow-fiber microporous membrane liquid-liquid extraction associated with 96-well plate system is proposed. • A supramolecular solvent was used as green extraction phase. • High sample throughput was achieved with this workflow. • Determination of six NSAID in urine was successfully performed. Nonsteroidal anti-inflammatory drugs (NSAIDs) are a class of drugs with antipyretic, analgesic, and anti-inflammatory effects widely used worldwide. This study aimed at developing an environmentally friendly and high-throughput sample preparation method for the determination of six NSAIDs in urine samples followed by high-performance liquid chromatography coupled to diode-array detection (HPLC-DAD). The experimental workflow consisted of hollow-fiber microporous membrane liquid-liquid extraction (HF-MMLLE) using a supramolecular solvent immobilized into the porous of polypropylene hollow membranes (1 cm length). These membranes were attached to a 96-well plate system to permit multiple extractions simultaneously. Under the optimized conditions, limits of detection (LODs) and limits of quantification (LOQs) ranged from 6.06 to 30.3 µg/L and from 20 to 100 µg/L, respectively. The linear ranges varied from 20 to 1000 µg/L for indomethacin and diclofenac, from 50 to 1000 µg/L for ketoprofen and ibuprofen, and from 100 to 1000 µg/L for naproxen and fenoprofen. The coefficients of determination (R²) ranged from 0.9735 to 0.9997. Intraday precision ranged from 6.13 to 20.11 %, interday precision varied from 2.87 to 20.72 %, and accuracy ranged from 92.49 to 126.89 %. Moreover, the recently proposed Sample Preparation Metric of Sustainability (SPMS) was employed to evaluate the greenness of the sample preparation technique resulting in a score of 8.0, which is highly satisfactory according to the concepts of green analytical chemistry.

Authors

Institutions

Publication Details

Journal
Green Analytical Chemistry
Published
2024-08-30
DOI
https://doi.org/10.1016/j.greeac.2024.100142
Citations
6
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
1.41

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A high-throughput sample preparation approach for the determination of nonsteroidal anti-inflammatory drugs in urine samples through membrane-based microextraction employing a green supramolecular solvent

Sofia Aquino Monteiro, Josias Merib, Camila Scheid, Carolina Souza Machado
6 citations
Green Analytical Chemistry
Analytical chemistry methods development
1.41
article

A high-throughput sample preparation approach for the determination of nonsteroidal anti-inflammatory drugs in urine samples through membrane-based microextraction employing a green supramolecular solvent

Sofia Aquino Monteiro, Josias Merib, Camila Scheid, Carolina Souza Machado
article en
6 citations

Abstract

• Hollow-fiber microporous membrane liquid-liquid extraction associated with 96-well plate system is proposed. • A supramolecular solvent was used as green extraction phase. • High sample throughput was achieved with this workflow. • Determination of six NSAID in urine was successfully performed. Nonsteroidal anti-inflammatory drugs (NSAIDs) are a class of drugs with antipyretic, analgesic, and anti-inflammatory effects widely used worldwide. This study aimed at developing an environmentally friendly and high-throughput sample preparation method for the determination of six NSAIDs in urine samples followed by high-performance liquid chromatography coupled to diode-array detection (HPLC-DAD). The experimental workflow consisted of hollow-fiber microporous membrane liquid-liquid extraction (HF-MMLLE) using a supramolecular solvent immobilized into the porous of polypropylene hollow membranes (1 cm length). These membranes were attached to a 96-well plate system to permit multiple extractions simultaneously. Under the optimized conditions, limits of detection (LODs) and limits of quantification (LOQs) ranged from 6.06 to 30.3 µg/L and from 20 to 100 µg/L, respectively. The linear ranges varied from 20 to 1000 µg/L for indomethacin and diclofenac, from 50 to 1000 µg/L for ketoprofen and ibuprofen, and from 100 to 1000 µg/L for naproxen and fenoprofen. The coefficients of determination (R²) ranged from 0.9735 to 0.9997. Intraday precision ranged from 6.13 to 20.11 %, interday precision varied from 2.87 to 20.72 %, and accuracy ranged from 92.49 to 126.89 %. Moreover, the recently proposed Sample Preparation Metric of Sustainability (SPMS) was employed to evaluate the greenness of the sample preparation technique resulting in a score of 8.0, which is highly satisfactory according to the concepts of green analytical chemistry.

Green Analytical ChemistryVol. 10
Universidade Federal de Ciências da Saúde de Porto Alegre (BR)
Conselho Nacional de Desenvolvimento Científico e Tecnológico
Openalex Percentile: Top 21%
Analytical chemistry methods development
1.41
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.