Correlation of tracer uptake in sentinel lymph nodes as measured on SPECT/CT and during intra-operative gamma tracing with SENSEI: the UZ Leuven experience

Abstract Purpose This retrospective analysis aims to study the relationship between tracer uptake in sentinel lymph nodes (SLNs) as measured on SPECT/CT and during intra-operative gamma tracing with a drop-in gamma probe (SENSEI ® ) in patients who participated in the UZ Leuven cohort of a prospective multicentre clinical trial evaluating the SENSEI ® probe for minimally-invasive SLN biopsy (SLNB) in prostate cancer. Correlation of pre- and intraoperative imaging can allow for improved surgical planning, providing important information to guide intraoperative findings. Methods Nine patients with histologically proven prostate cancer scheduled for radical prostatectomy (RP) with extended pelvic lymph node dissection (ePLND) were prospectively selected for preoperative lymphoscintigraphy with SPECT/CT the day before surgery after intra-prostatic injection of 240 MBq of 99m Tc-nanocolloid under ultrasound guidance. SLNB was performed with the SENSEI ® drop-in gamma probe during standard of care RP with ePLND. SLN detection and counts on SPECT/CT and in vivo and ex vivo probe measurements were compared. Results The patient-based detection rate of at least one SLN was 100% on SPECT/CT and 100% intraoperatively with the drop-in gamma probe. In total, 29 SLNs were detected with the probe and 32 SLNs on SPECT/CT. The correlation between SPECT/CT counts and in vivo and ex vivo probe measurements was significant but moderate (Pearson r = 0.57, p = 0.002 and r = 0.64, p = 0.0003, respectively). Conclusions Drop-in gamma probe measurements showed a moderate correlation with the SPECT/CT counts. SPECT/CT uptake values can be used as an estimate for in vivo detection of SLNs with the probe.

Authors

Institutions

Publication Details

Journal
Clinical and Translational Imaging
Published
2024-08-30
DOI
https://doi.org/10.1007/s40336-024-00654-z
Citations
2
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
0.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Correlation of tracer uptake in sentinel lymph nodes as measured on SPECT/CT and during intra-operative gamma tracing with SENSEI: the UZ Leuven experience

Wouter Everaerts, Sander Jentjens, Liesbeth De Wever, Karolien Goffin et al.
2 citations
Clinical and Translational Imaging
Radiomics and Machine Learning in Medical Imaging
0.81
article

Correlation of tracer uptake in sentinel lymph nodes as measured on SPECT/CT and during intra-operative gamma tracing with SENSEI: the UZ Leuven experience

Wouter Everaerts, Sander Jentjens, Liesbeth De Wever, Karolien Goffin, Christophe M. Deroose, Martin Manley
article en
2 citations

Abstract

Abstract Purpose This retrospective analysis aims to study the relationship between tracer uptake in sentinel lymph nodes (SLNs) as measured on SPECT/CT and during intra-operative gamma tracing with a drop-in gamma probe (SENSEI ® ) in patients who participated in the UZ Leuven cohort of a prospective multicentre clinical trial evaluating the SENSEI ® probe for minimally-invasive SLN biopsy (SLNB) in prostate cancer. Correlation of pre- and intraoperative imaging can allow for improved surgical planning, providing important information to guide intraoperative findings. Methods Nine patients with histologically proven prostate cancer scheduled for radical prostatectomy (RP) with extended pelvic lymph node dissection (ePLND) were prospectively selected for preoperative lymphoscintigraphy with SPECT/CT the day before surgery after intra-prostatic injection of 240 MBq of 99m Tc-nanocolloid under ultrasound guidance. SLNB was performed with the SENSEI ® drop-in gamma probe during standard of care RP with ePLND. SLN detection and counts on SPECT/CT and in vivo and ex vivo probe measurements were compared. Results The patient-based detection rate of at least one SLN was 100% on SPECT/CT and 100% intraoperatively with the drop-in gamma probe. In total, 29 SLNs were detected with the probe and 32 SLNs on SPECT/CT. The correlation between SPECT/CT counts and in vivo and ex vivo probe measurements was significant but moderate (Pearson r = 0.57, p = 0.002 and r = 0.64, p = 0.0003, respectively). Conclusions Drop-in gamma probe measurements showed a moderate correlation with the SPECT/CT counts. SPECT/CT uptake values can be used as an estimate for in vivo detection of SLNs with the probe.

Clinical and Translational ImagingVol. 12(6)
KU Leuven (BE)
Good health and well-being
Openalex Percentile: Top 26%
Radiomics and Machine Learning in Medical Imaging
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.