Pola Tahanan Pentanahan Tower Saluran Udara Tegangan Tinggi (SUTT) 150 KV Sekarputih – Ngoro

The electrode rods in the grounding system of the High Voltage transmission tower that are embedded in the ground will experience changes in grounding resistance values ​​over time. If the grounding resistance value increases and exceeds the set standard, which is <10 Ω, then immediate repairs need to be made. This research was conducted on the 150 kV High Voltage transmission tower from Sekarputih to Ngoro using the Earth Tester tool. The purpose of this study was to find the right method to improve grounding resistance on the 150 kV High Voltage tower that has high impedance to comply with the standard. The results of measurements in the field showed that there were 3 towers with high grounding resistance values, which exceeded <10 Ω, which required immediate repairs.

Authors

Institutions

Publication Details

Journal
Jurnal Penelitian Rumpun Ilmu Teknik
Published
2024-08-12
DOI
https://doi.org/10.55606/juprit.v3i3.4202
Primary Topic
Legal Studies and Policies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pola Tahanan Pentanahan Tower Saluran Udara Tegangan Tinggi (SUTT) 150 KV Sekarputih – Ngoro

Bambang Minto Basuki, Adi Noerhamsyah
Jurnal Penelitian Rumpun Ilmu Teknik
Legal Studies and Policies
article

Pola Tahanan Pentanahan Tower Saluran Udara Tegangan Tinggi (SUTT) 150 KV Sekarputih – Ngoro

Bambang Minto Basuki, Adi Noerhamsyah
article en

Abstract

The electrode rods in the grounding system of the High Voltage transmission tower that are embedded in the ground will experience changes in grounding resistance values ​​over time. If the grounding resistance value increases and exceeds the set standard, which is <10 Ω, then immediate repairs need to be made. This research was conducted on the 150 kV High Voltage transmission tower from Sekarputih to Ngoro using the Earth Tester tool. The purpose of this study was to find the right method to improve grounding resistance on the 150 kV High Voltage tower that has high impedance to comply with the standard. The results of measurements in the field showed that there were 3 towers with high grounding resistance values, which exceeded <10 Ω, which required immediate repairs.

Jurnal Penelitian Rumpun Ilmu TeknikVol. 3(3)
Universitas Islam Malang (ID)
Openalex Percentile: Top 74%
Legal Studies and Policies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Pola Tahanan Pentanahan Tower Saluran Udara Tegangan Tinggi (SUTT) 150 KV Sekarputih – Ngoro — Bambang Minto Basuki, Adi Noerhamsyah · Jurnal Penelitian Rumpun Ilmu Teknik (2024) | TGRS Research Map | TGRS