Light‐Broadened Faradaic Regime of Organic Electrochemical Transistors for Accelerated Amperometric Biodetection

Abstract Faradaic‐mode organic electrochemical transistors (OECT) are promising but usually need hundreds of millivolts to sustain redox reactions. Decrease or even removal of the voltage penalty is highly desirable. Herein, the Faradic regime of the OECT is broadened toward zero bias by integrating a p‐n heterojunction of Cu 2 S‐diethylenetriamine (DETA)‐CdS for efficient photogating of poly(3,4‐ethylenedioxythiophene): poly(styrene sulfonate) channel. Upon light illumination, it is found that an obvious Faradaic process is evolved at the gate/electrolyte interface under zero gate bias, suggesting the potential of sensitive amperometric biodetection with enhanced signal resolution. At the Cu 2 S‐DETA‐CdS/liquid interface, a biosensing process is introduced, combining with a DNA walker and enzymatic biocatalytic precipitation to produce a target‐dependent diffusion barrier, modulating the amperometric output with enhanced signal variations under light irradiation compared to that in the dark. The proposed system achieves the desired analytical performance for representative target miRNA‐10b with a low detection limit of 0.21 fM. This work features a light‐mediated OECT device with enhanced signal resolution and provides new operational paradigms and insights for novel optoelectronics interfacing with biological systems.

Authors

Institutions

Publication Details

Journal
Advanced Functional Materials
Published
2024-08-29
DOI
https://doi.org/10.1002/adfm.202409153
Citations
14
Primary Topic
Conducting polymers and applications
Type
article
Field-Weighted Citation Impact
2.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Light‐Broadened Faradaic Regime of Organic Electrochemical Transistors for Accelerated Amperometric Biodetection

Weiwei Zhao, Tiantong Jiang, Yi‐Tong Xu, Xiaofan Zhai et al.
14 citations
Advanced Functional Materials
Conducting polymers and applications
2.36
article

Light‐Broadened Faradaic Regime of Organic Electrochemical Transistors for Accelerated Amperometric Biodetection

Weiwei Zhao, Tiantong Jiang, Yi‐Tong Xu, Xiaofan Zhai, Xingwu Jiang, Zhaoxia Lu, Peng Ju, Jin Hu, Jingtian Chi
article en
14 citations

Abstract

Abstract Faradaic‐mode organic electrochemical transistors (OECT) are promising but usually need hundreds of millivolts to sustain redox reactions. Decrease or even removal of the voltage penalty is highly desirable. Herein, the Faradic regime of the OECT is broadened toward zero bias by integrating a p‐n heterojunction of Cu 2 S‐diethylenetriamine (DETA)‐CdS for efficient photogating of poly(3,4‐ethylenedioxythiophene): poly(styrene sulfonate) channel. Upon light illumination, it is found that an obvious Faradaic process is evolved at the gate/electrolyte interface under zero gate bias, suggesting the potential of sensitive amperometric biodetection with enhanced signal resolution. At the Cu 2 S‐DETA‐CdS/liquid interface, a biosensing process is introduced, combining with a DNA walker and enzymatic biocatalytic precipitation to produce a target‐dependent diffusion barrier, modulating the amperometric output with enhanced signal variations under light irradiation compared to that in the dark. The proposed system achieves the desired analytical performance for representative target miRNA‐10b with a low detection limit of 0.21 fM. This work features a light‐mediated OECT device with enhanced signal resolution and provides new operational paradigms and insights for novel optoelectronics interfacing with biological systems.

Advanced Functional MaterialsVol. 34(49)
Guangxi University (CN), Chinese Academy of Sciences (CN), Ministry of Natural Resources (CN), Institute of Oceanology (CN), First Institute of Oceanography (CN), Guangxi Academy of Sciences (CN), Nanjing University (CN)
National Natural Science Foundation of China, Basic Scientific Fund for National Public Research Institutes of China
Responsible consumption and production
Openalex Percentile: Top 11%
Conducting polymers and applications
2.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.