CIP under Pressure: Rethinking Solutions to the CAVSARP System’s High Head without Breaking the Bank

The Central Avra Valley Storage and Recovery Project (CAVSARP) was designed to recharge and recover Central Arizona Project (CAP) water in response to water quality issues in Tucson and is supplied by 60-in. welded steel pipe (WSP) and a 54-in. high-density polyurethane (HDPE) pipe. As a pressure system, the head characteristics have been a challenge, since CAVSARP was commissioned. There is a large elevation difference upstream to downstream, so control valve cavitation is a concern at the upstream turnouts with downstream turnouts experiencing low head issues. In 2019, the HDPE transmission main suffered a pipe failure, a 100-ft longitudinal crack. Though pipe replacement was recommended, replacing the flow control valves with plug valves was determined to be a viable alternative. After evaluation of several valves, a 20-in. eccentric plug valve proved to be a suitable solution for CAVSARP’s conditions and saved the utility’s CIP budget $18 million by avoiding pipe replacement.

Authors

Institutions

Publication Details

Published
2024-08-30
DOI
https://doi.org/10.1061/9780784485569.022
Primary Topic
Economic Theory and Policy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CIP under Pressure: Rethinking Solutions to the CAVSARP System’s High Head without Breaking the Bank

Michael Georgalas, Todd L. Crouthamel, Gary Brady, Tess C. Degginger et al.
Economic Theory and Policy
article

CIP under Pressure: Rethinking Solutions to the CAVSARP System’s High Head without Breaking the Bank

Michael Georgalas, Todd L. Crouthamel, Gary Brady, Tess C. Degginger, Fletcher McKenzie
article en

Abstract

The Central Avra Valley Storage and Recovery Project (CAVSARP) was designed to recharge and recover Central Arizona Project (CAP) water in response to water quality issues in Tucson and is supplied by 60-in. welded steel pipe (WSP) and a 54-in. high-density polyurethane (HDPE) pipe. As a pressure system, the head characteristics have been a challenge, since CAVSARP was commissioned. There is a large elevation difference upstream to downstream, so control valve cavitation is a concern at the upstream turnouts with downstream turnouts experiencing low head issues. In 2019, the HDPE transmission main suffered a pipe failure, a 100-ft longitudinal crack. Though pipe replacement was recommended, replacing the flow control valves with plug valves was determined to be a viable alternative. After evaluation of several valves, a 20-in. eccentric plug valve proved to be a suitable solution for CAVSARP’s conditions and saved the utility’s CIP budget $18 million by avoiding pipe replacement.

Stantec (United States) (US), Stantec (Canada) (CA)
Decent work and economic growth
Openalex Percentile: Top 74%
Economic Theory and Policy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.