Southern Nevada Water Authority Stage II Reliability Upgrades Project: Transient Analysis of 341 ML/d (90 MGD) Monthill Pumping Station and 681 ML/d (180 MGD) Hacienda Pumping Station

A transient analysis was completed for the 341 megaliters per day (ML/d) (90 MGD) Monthill Pumping Station (PS) that will provide redundancy for the 681 ML/d (180 MGD) Hacienda PS—a critical facility serving the central area of Las Vegas. A comprehensive transient analysis was carried out to identify and mitigate potentially damaging water hammer conditions with the Monthill and Hacienda PS’s operating alone, as well as concurrently. This paper will review the use of direct-on-line starters versus soft-starters; using non-slam check valves in conjunction with pump control valves; results with a throttled air chamber; and methodology used to recommend pump control valve opening and closing times.

Authors

Institutions

Publication Details

Published
2024-08-30
DOI
https://doi.org/10.1061/9780784485569.055
Primary Topic
Geotechnical Engineering and Underground Structures
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Southern Nevada Water Authority Stage II Reliability Upgrades Project: Transient Analysis of 341 ML/d (90 MGD) Monthill Pumping Station and 681 ML/d (180 MGD) Hacienda Pumping Station

Michael Georgalas, Jonathan Tull
Geotechnical Engineering and Underground Structures
article

Southern Nevada Water Authority Stage II Reliability Upgrades Project: Transient Analysis of 341 ML/d (90 MGD) Monthill Pumping Station and 681 ML/d (180 MGD) Hacienda Pumping Station

Michael Georgalas, Jonathan Tull
article en

Abstract

A transient analysis was completed for the 341 megaliters per day (ML/d) (90 MGD) Monthill Pumping Station (PS) that will provide redundancy for the 681 ML/d (180 MGD) Hacienda PS—a critical facility serving the central area of Las Vegas. A comprehensive transient analysis was carried out to identify and mitigate potentially damaging water hammer conditions with the Monthill and Hacienda PS’s operating alone, as well as concurrently. This paper will review the use of direct-on-line starters versus soft-starters; using non-slam check valves in conjunction with pump control valves; results with a throttled air chamber; and methodology used to recommend pump control valve opening and closing times.

Southern Nevada Water Authority (US), Stantec (United States) (US), Stantec (Canada) (CA)
Clean water and sanitation
Openalex Percentile: Top 84%
Geotechnical Engineering and Underground Structures
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.