Comprehensive Condition Assessment Improves Reliability of a 150-Year-Old Critical Water Transmission Main

The Greenmount Avenue Water Transmission Main is a 150-year-old 36-in. diameter pit cast iron pipe, a critical asset in the Baltimore’s water distribution system. With aging water main and the history of breaks, the City decided to conduct full condition assessment of this critical supply main, with the primary objective to determine the remaining useful life of the pipeline. Various condition assessment methods used included Forensic Analysis of the pipe coupons, Soil Chemistry Analysis, Visual Inspection of the exterior of the pipeline, and Leak Detection and Closed Circuit Television (CCTV) Inspection. This case study focuses on the methodology, findings, results of the condition assessment, and proposed measures to improve the reliability of this important asset.

Authors

Institutions

Publication Details

Published
2024-08-30
DOI
https://doi.org/10.1061/9780784485583.023
Primary Topic
Water Systems and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comprehensive Condition Assessment Improves Reliability of a 150-Year-Old Critical Water Transmission Main

Vennila Durai, Nirav K. Shah, Brian Ball
Water Systems and Optimization
article

Comprehensive Condition Assessment Improves Reliability of a 150-Year-Old Critical Water Transmission Main

Vennila Durai, Nirav K. Shah, Brian Ball
article en

Abstract

The Greenmount Avenue Water Transmission Main is a 150-year-old 36-in. diameter pit cast iron pipe, a critical asset in the Baltimore’s water distribution system. With aging water main and the history of breaks, the City decided to conduct full condition assessment of this critical supply main, with the primary objective to determine the remaining useful life of the pipeline. Various condition assessment methods used included Forensic Analysis of the pipe coupons, Soil Chemistry Analysis, Visual Inspection of the exterior of the pipeline, and Leak Detection and Closed Circuit Television (CCTV) Inspection. This case study focuses on the methodology, findings, results of the condition assessment, and proposed measures to improve the reliability of this important asset.

Baltimore City Public Schools (US), Xylem (United States) (US), University of Baltimore (US)
Clean water and sanitation
Openalex Percentile: Top 84%
Water Systems and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.