Sewer Pipeline Material Selection Is Easy, Right? It’s More Complex Than You Might Think

The City of San Mateo, CA, commissioned the planning, preliminary design, and final design of the Basins 2 and 3 Collection System Improvements (CSI) Project (herein referred to as the Project) with an objective of mitigating Sanitary Sewer Overflows (SSOs) within a large section of the City. To achieve the objective, the project identified locations in the City’s sewer system that were under capacity by utilizing hydraulic modeling to pinpoint areas of the sewer network prone to SSOs during wet weather events. Results of the hydraulic modeling led to development of several sewer design packages to enhance the collection system’s capacity to mitigate SSO occurrences. Each design package utilized various construction techniques and a variety of pipe materials. This paper provides a project case study and focuses on the details of the engineering solutions and the rationale behind why the selected pipeline materials were chosen.

Authors

Institutions

Publication Details

Published
2024-08-30
DOI
https://doi.org/10.1061/9780784485569.020
Primary Topic
Geotechnical Engineering and Underground Structures
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sewer Pipeline Material Selection Is Easy, Right? It’s More Complex Than You Might Think

Matthew Alcock, Scott Williamson, Noel Guercio, Deryk Daquigan
Geotechnical Engineering and Underground Structures
article

Sewer Pipeline Material Selection Is Easy, Right? It’s More Complex Than You Might Think

Matthew Alcock, Scott Williamson, Noel Guercio, Deryk Daquigan
article en

Abstract

The City of San Mateo, CA, commissioned the planning, preliminary design, and final design of the Basins 2 and 3 Collection System Improvements (CSI) Project (herein referred to as the Project) with an objective of mitigating Sanitary Sewer Overflows (SSOs) within a large section of the City. To achieve the objective, the project identified locations in the City’s sewer system that were under capacity by utilizing hydraulic modeling to pinpoint areas of the sewer network prone to SSOs during wet weather events. Results of the hydraulic modeling led to development of several sewer design packages to enhance the collection system’s capacity to mitigate SSO occurrences. Each design package utilized various construction techniques and a variety of pipe materials. This paper provides a project case study and focuses on the details of the engineering solutions and the rationale behind why the selected pipeline materials were chosen.

Stantec (United States) (US), Stantec (Canada) (CA)
Openalex Percentile: Top 84%
Geotechnical Engineering and Underground Structures
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.