Salvaging intraluminal peritoneal dialysis catheter obstruction from blood clot with a targeted thrombolytic agent: an innovation

Peritoneal dialysis (PD) catheter malfunction commonly leads to the removal of the catheter and eventually to a transfer to hemodialysis. The most common cause is intraluminal obstruction caused by blood and fibrin clots. Recommended interventions include irrigation of the catheter with heparinized saline; if this method fails, thrombolytic agents may be used. Mechanical methods such as intraluminal brushing are also utilized, typically after medical treatment fails. Here, we present a case of a patient who developed an intraluminal blood clot that persisted despite attempts with intraluminal thrombolytic drugs and intraluminal brushing. To salvage the catheter, targeted thrombolysis was performed using an endoscopic retrograde cholangiopancreatography (ERCP) guidewire to reinforce the coiled PD catheter and puncture the clots. Additionally, a Swing Tip cannula was employed for direct injection of the thrombolytic agent. These interventions successfully preserved the catheter, resolving the clot and ensuring continued functionality.

Authors

Institutions

Publication Details

Journal
Journal of Nephrology
Published
2024-08-30
DOI
https://doi.org/10.1007/s40620-024-02075-7
Primary Topic
Dialysis and Renal Disease Management
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Salvaging intraluminal peritoneal dialysis catheter obstruction from blood clot with a targeted thrombolytic agent: an innovation

Athiphat Banjongjit, Talerngsak Kanjanabuch, Piyaporn Towannang, Rungsun Rerknimitr et al.
Journal of Nephrology
Dialysis and Renal Disease Management
article

Salvaging intraluminal peritoneal dialysis catheter obstruction from blood clot with a targeted thrombolytic agent: an innovation

Athiphat Banjongjit, Talerngsak Kanjanabuch, Piyaporn Towannang, Rungsun Rerknimitr, Pacharida Kinpayom
article en

Abstract

Peritoneal dialysis (PD) catheter malfunction commonly leads to the removal of the catheter and eventually to a transfer to hemodialysis. The most common cause is intraluminal obstruction caused by blood and fibrin clots. Recommended interventions include irrigation of the catheter with heparinized saline; if this method fails, thrombolytic agents may be used. Mechanical methods such as intraluminal brushing are also utilized, typically after medical treatment fails. Here, we present a case of a patient who developed an intraluminal blood clot that persisted despite attempts with intraluminal thrombolytic drugs and intraluminal brushing. To salvage the catheter, targeted thrombolysis was performed using an endoscopic retrograde cholangiopancreatography (ERCP) guidewire to reinforce the coiled PD catheter and puncture the clots. Additionally, a Swing Tip cannula was employed for direct injection of the thrombolytic agent. These interventions successfully preserved the catheter, resolving the clot and ensuring continued functionality.

Journal of NephrologyVol. 37(7)
Chulalongkorn University (TH), Bangkok Hospital (TH), King Chulalongkorn Memorial Hospital (TH)
Faculty of Medicine, Chulalongkorn University
Industry, innovation and infrastructure
Openalex Percentile: Top 81%
Dialysis and Renal Disease Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.