Experimental Study on the Endwall Aerothermal Performance of Turbine Cascades in a Novel Transient Test Facility

Abstract Linear turbine cascades have been widely used to conduct fundamental and applied investigations, but only a few transient test facilities with the linear turbine cascade are available in the open literature. A novel transient test facility was presented in this paper, including detailed design and structure, and various experimental measurements (aerodynamic and thermodynamic) were conducted to verify the transient test facility’s capability. This test facility mainly includes a main air supply line (bypass line and test line), a coolant supply line, a test section, and a control system (heater and various valves). The linear cascade holds up six equally spaced cascade profiles, forming five completed cascade passages, and the center passage is used for aerodynamic and thermodynamic measurements. The aerodynamic loss and heat transfer performance were measured at various flow conditions (incidence angle, Ma, and blowing ratio (BR)). The endwall heat transfer coefficient and film cooling effectiveness were estimated by adopting a dual linear regression technique. Results indicate that the mianstream pressure and temperature present a desired step change, and remain relatively steady in the test window. The magnitudes of endwall heat transfer significantly increase as the Maex increases from 0.2 to 0.5, but the thermal load distributions remain the same. The BR is a key parameter for endwall film cooling performance, and the optimal film cooling coverage is acquired at the critical value of BR. Both insufficient and excessive coolant flowrate can result in undesirable endwall film cooling coverage, and may cause unnecessary consumption of the coolant flow.

Authors

Institutions

Publication Details

Journal
Journal of Thermal Science and Engineering Applications
Published
2024-08-30
DOI
https://doi.org/10.1115/1.4066406
Citations
2
Primary Topic
Turbomachinery Performance and Optimization
Type
article
Field-Weighted Citation Impact
2.60

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Study on the Endwall Aerothermal Performance of Turbine Cascades in a Novel Transient Test Facility

Wing F. Ng, Mingyang Hao, Bofeng Bai, Jun Li et al.
2 citations
Journal of Thermal Science and Engineering Applications
Turbomachinery Performance and Optimization
2.60
article

Experimental Study on the Endwall Aerothermal Performance of Turbine Cascades in a Novel Transient Test Facility

Wing F. Ng, Mingyang Hao, Bofeng Bai, Jun Li, Shuo Mao, Zhigang Li, Yuanyuan Li
article en
2 citations

Abstract

Abstract Linear turbine cascades have been widely used to conduct fundamental and applied investigations, but only a few transient test facilities with the linear turbine cascade are available in the open literature. A novel transient test facility was presented in this paper, including detailed design and structure, and various experimental measurements (aerodynamic and thermodynamic) were conducted to verify the transient test facility’s capability. This test facility mainly includes a main air supply line (bypass line and test line), a coolant supply line, a test section, and a control system (heater and various valves). The linear cascade holds up six equally spaced cascade profiles, forming five completed cascade passages, and the center passage is used for aerodynamic and thermodynamic measurements. The aerodynamic loss and heat transfer performance were measured at various flow conditions (incidence angle, Ma, and blowing ratio (BR)). The endwall heat transfer coefficient and film cooling effectiveness were estimated by adopting a dual linear regression technique. Results indicate that the mianstream pressure and temperature present a desired step change, and remain relatively steady in the test window. The magnitudes of endwall heat transfer significantly increase as the Maex increases from 0.2 to 0.5, but the thermal load distributions remain the same. The BR is a key parameter for endwall film cooling performance, and the optimal film cooling coverage is acquired at the critical value of BR. Both insufficient and excessive coolant flowrate can result in undesirable endwall film cooling coverage, and may cause unnecessary consumption of the coolant flow.

Journal of Thermal Science and Engineering ApplicationsVol. 16(11)
Thermal Power Research Institute (CN), Goodwin College (US), Virginia Tech (US), Xi'an Jiaotong University (CN)
National Natural Science Foundation of China, China Postdoctoral Science Foundation
Affordable and clean energy
Openalex Percentile: Top 8%
Turbomachinery Performance and Optimization
2.60
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.