Fibrin clot permeability (Ks) in patients on left ventricular assist device

Patients on left ventricular assist devices (LVAD) are prone to excessive hemostasis disturbances due to permanent contact of artificial pump surfaces with blood components. We aimed to investigate if fibrin clot permeability is altered in patients on long-term continuous-flow LVAD therapy and if the clot permeability is associated with clinical characteristics and adverse events. We investigated 85 end-stage heart failure patients (90.6% men, age 48.6-63.8 years) scheduled for continuous flow long-term LVAD support according to current clinical indications. The patients were assessed periodically: prior to LVAD implantation (T1), 3-6 months (T2) after LVAD implantation, 6-12 months after (T3) and then every 6 months. We tested the first three blood samples (T1-T3) and the last available blood sample (T4), but no longer than 5 years after LVAD implantation. We assessed hemostasis parameters (Activated Partial Thromboplastin Time (APTT) Prothrombin Time, Activated Partial Thromboplastin Time, Fibrinogen, D-dimer, Antithrombin, Thrombin Time, Factor VIII, and von Willebrand Factor, aspirin-induced platelet inhibition, adenosine-diphosphate test) changes during the study period. Fibrin Clot Permeability was evaluated using a pressure system and Permeability Coefficient (Ks) was calculated. We observed a decrease in fibrin clot permeability (Ks) between T1, T2, T3 and T4 time periods; P < 0.01 for each comparison. Fibrin clot permeability was negatively correlated with fibrinogen concentration: r = - 0.51, P < 0.001, factor VIII activity r = - 0.42, P < 0.001. There was no association of Ks with age, Left Ventricular Ejection Fraction (LVEF) and medications P > 0.001, however cumulative measurements in patients on aspirin showed shortening of Ks in this group P = 0.0123. Major adverse cardiac and cerebrovascular events (MACCE) occurred in 36.5% patients, bleeding events in 25.9%, Net Adverse Clinical Events (NACE) in 62.4%; 31.7% patients died, and 17.6% underwent transplantation. The transplantation was considered as the endpoint. Discrepancies in Ks were observed between patients with MACCE, bleeding, and NACE, and patients without adverse events. Ks showed a constant trend towards normalization (P < 0.01) only in patients without adverse events. Patients with advanced heart failure have disturbed clot structure. A trend towards normalization of the Ks values is associated with fewer thromboembolic and bleeding complications in this group of patients.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-08-30
DOI
https://doi.org/10.1038/s41598-024-69665-0
Citations
2
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fibrin clot permeability (Ks) in patients on left ventricular assist device

Jacek Kaczmarski, Piotr Przybyłowski, Bartosz Hudzik, Szymon Pawlak et al.
2 citations
Scientific Reports
Mechanical Circulatory Support Devices
0.37
article

Fibrin clot permeability (Ks) in patients on left ventricular assist device

Jacek Kaczmarski, Piotr Przybyłowski, Bartosz Hudzik, Szymon Pawlak, Agnieszka Kuczaj, Tomasz Hrapkowicz, Michał Skrzypek
article en
2 citations

Abstract

Patients on left ventricular assist devices (LVAD) are prone to excessive hemostasis disturbances due to permanent contact of artificial pump surfaces with blood components. We aimed to investigate if fibrin clot permeability is altered in patients on long-term continuous-flow LVAD therapy and if the clot permeability is associated with clinical characteristics and adverse events. We investigated 85 end-stage heart failure patients (90.6% men, age 48.6-63.8 years) scheduled for continuous flow long-term LVAD support according to current clinical indications. The patients were assessed periodically: prior to LVAD implantation (T1), 3-6 months (T2) after LVAD implantation, 6-12 months after (T3) and then every 6 months. We tested the first three blood samples (T1-T3) and the last available blood sample (T4), but no longer than 5 years after LVAD implantation. We assessed hemostasis parameters (Activated Partial Thromboplastin Time (APTT) Prothrombin Time, Activated Partial Thromboplastin Time, Fibrinogen, D-dimer, Antithrombin, Thrombin Time, Factor VIII, and von Willebrand Factor, aspirin-induced platelet inhibition, adenosine-diphosphate test) changes during the study period. Fibrin Clot Permeability was evaluated using a pressure system and Permeability Coefficient (Ks) was calculated. We observed a decrease in fibrin clot permeability (Ks) between T1, T2, T3 and T4 time periods; P < 0.01 for each comparison. Fibrin clot permeability was negatively correlated with fibrinogen concentration: r = - 0.51, P < 0.001, factor VIII activity r = - 0.42, P < 0.001. There was no association of Ks with age, Left Ventricular Ejection Fraction (LVEF) and medications P > 0.001, however cumulative measurements in patients on aspirin showed shortening of Ks in this group P = 0.0123. Major adverse cardiac and cerebrovascular events (MACCE) occurred in 36.5% patients, bleeding events in 25.9%, Net Adverse Clinical Events (NACE) in 62.4%; 31.7% patients died, and 17.6% underwent transplantation. The transplantation was considered as the endpoint. Discrepancies in Ks were observed between patients with MACCE, bleeding, and NACE, and patients without adverse events. Ks showed a constant trend towards normalization (P < 0.01) only in patients without adverse events. Patients with advanced heart failure have disturbed clot structure. A trend towards normalization of the Ks values is associated with fewer thromboembolic and bleeding complications in this group of patients.

Scientific ReportsVol. 14(1)
Medical University of Silesia (PL), Silesian Center for Heart Disease (PL)
Openalex Percentile: Top 44%
Mechanical Circulatory Support Devices
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.