Monitoring sedimentation of magnetorheological fluids using an infrared night vision wide-angle lens visual monitoring system with dynamic calibration method

Magnetorheological fluids (MRFs) have demonstrated remarkable potential in engineering vibration damping. Nonetheless, the substantial density difference between the dispersed phase and the dispersing medium causes inevitable sedimentation in MRFs, significantly affecting the material’s service life and restricting its engineering applications. Monitoring technology for MRF sedimentation plays a crucial role in comprehending sedimentation behavior and holds significant importance for the subsequent redispersion of MRFs. Consequently, the monitoring technology for MRFs has been gaining increasing attention in recent times. This study proposes a machine vision-based real-time and in situ monitoring method to test and evaluate the suspension stability of MRFs. Firstly, an infrared wide-angle night vision lens (IWNVL) is fixed at the side of a MRF column for capturing the sequential MRF images during its sediment process. Then, the gray values (GVs) could be obtained by utilizing Gaussian filtering and morphological filtering. Secondly, by combining the Kynch sedimentation theory and Lambert-Beer composite material optical transmission theory, an analytic model is established in this works to find the relationship between the MRFs’ concentration gradient to its GVs. In what follows, the concentration distribution varied with time could be tested by the GVs of the sequential MRF images. Finally, a sentimental experiment for prepared MRF column is carried out in this works, and the testing results are verified and discussed by a capacitance sensor and a simple visual observation. The experimental results demonstrate that the proposed method could accurately measure the concentration distribution during MRFs’ sedimentation process under different initial light intensities.

Authors

Institutions

Publication Details

Journal
Journal of Intelligent Material Systems and Structures
Published
2024-08-30
DOI
https://doi.org/10.1177/1045389x241271940
Citations
1
Primary Topic
Vibration Control and Rheological Fluids
Type
article
Field-Weighted Citation Impact
0.26
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Monitoring sedimentation of magnetorheological fluids using an infrared night vision wide-angle lens visual monitoring system with dynamic calibration method

Shiwei Chen, Honghui Zhang, Pan Jiang, Jie Yang et al.
1 citations
Journal of Intelligent Material Systems and Structures
Vibration Control and Rheological Fluids
0.26
article

Monitoring sedimentation of magnetorheological fluids using an infrared night vision wide-angle lens visual monitoring system with dynamic calibration method

Shiwei Chen, Honghui Zhang, Pan Jiang, Jie Yang, Yang He
article en
1 citations

Abstract

Magnetorheological fluids (MRFs) have demonstrated remarkable potential in engineering vibration damping. Nonetheless, the substantial density difference between the dispersed phase and the dispersing medium causes inevitable sedimentation in MRFs, significantly affecting the material’s service life and restricting its engineering applications. Monitoring technology for MRF sedimentation plays a crucial role in comprehending sedimentation behavior and holds significant importance for the subsequent redispersion of MRFs. Consequently, the monitoring technology for MRFs has been gaining increasing attention in recent times. This study proposes a machine vision-based real-time and in situ monitoring method to test and evaluate the suspension stability of MRFs. Firstly, an infrared wide-angle night vision lens (IWNVL) is fixed at the side of a MRF column for capturing the sequential MRF images during its sediment process. Then, the gray values (GVs) could be obtained by utilizing Gaussian filtering and morphological filtering. Secondly, by combining the Kynch sedimentation theory and Lambert-Beer composite material optical transmission theory, an analytic model is established in this works to find the relationship between the MRFs’ concentration gradient to its GVs. In what follows, the concentration distribution varied with time could be tested by the GVs of the sequential MRF images. Finally, a sentimental experiment for prepared MRF column is carried out in this works, and the testing results are verified and discussed by a capacitance sensor and a simple visual observation. The experimental results demonstrate that the proposed method could accurately measure the concentration distribution during MRFs’ sedimentation process under different initial light intensities.

Journal of Intelligent Material Systems and StructuresVol. 36(10)
Chongqing University (CN), Chongqing University of Science and Technology (CN), China Academy of Information and Communications Technology (CN)
Openalex Percentile: Top 45%
Vibration Control and Rheological Fluids
0.26
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.