Comprehensive Analysis of Magnetic Flux Density and RF-EMF Exposure in Electric Buses: A Case Study from Samsun, Turkey

This study investigates magnetic flux density (B) and radiofrequency electromagnetic field (RF-EMF) measurements on electric buses operating in Samsun, Turkey, focusing on two bus routes (called E1 and E4) during the morning and evening hours. Measurements were taken under diverse operational conditions, including acceleration, cruising, and braking, at locations of peak passenger density. Along the E1 route, the magnetic field intensity varied significantly based on the bus position, road slope, and passenger load, with notable increases during braking. In contrast, the E4 route showed a lower magnetic field intensity and RF-EMF values due to its straighter trajectory and reduced operational stops. The highest RF-EMF measurement recorded was 6.01 V/m, which is below the maximum levels established by the ICNIRP guidelines. In 11 out of the 12 different band-selective RF-EMF measurements, the highest contribution came from the downlink band of the base stations, while in only one measurement, the highest contribution originated from the uplink bands of the base stations. All data were subject to the Anderson-Darling test, confirming the generalized extreme value distribution as the best fit for both B and RF-EMF measurements. Additionally, the study assessed B levels inside and outside the bus during charging, revealing heightened readings near the pantograph. These findings significantly contribute to our understanding of electromagnetic field exposure in electric bus environments, highlighting potential health implications and informing the development of targeted mitigation strategies.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-08-30
DOI
https://doi.org/10.3390/s24175634
Citations
4
Primary Topic
Electromagnetic Fields and Biological Effects
Type
article
Field-Weighted Citation Impact
2.65
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comprehensive Analysis of Magnetic Flux Density and RF-EMF Exposure in Electric Buses: A Case Study from Samsun, Turkey

Adnan Ahmad Cheema, Çetin Kurnaz, Teoman Karadağ, Zafer Emre Albayrak
4 citations
Sensors
Electromagnetic Fields and Biological Effects
2.65
article

Comprehensive Analysis of Magnetic Flux Density and RF-EMF Exposure in Electric Buses: A Case Study from Samsun, Turkey

Adnan Ahmad Cheema, Çetin Kurnaz, Teoman Karadağ, Zafer Emre Albayrak
article en
4 citations

Abstract

This study investigates magnetic flux density (B) and radiofrequency electromagnetic field (RF-EMF) measurements on electric buses operating in Samsun, Turkey, focusing on two bus routes (called E1 and E4) during the morning and evening hours. Measurements were taken under diverse operational conditions, including acceleration, cruising, and braking, at locations of peak passenger density. Along the E1 route, the magnetic field intensity varied significantly based on the bus position, road slope, and passenger load, with notable increases during braking. In contrast, the E4 route showed a lower magnetic field intensity and RF-EMF values due to its straighter trajectory and reduced operational stops. The highest RF-EMF measurement recorded was 6.01 V/m, which is below the maximum levels established by the ICNIRP guidelines. In 11 out of the 12 different band-selective RF-EMF measurements, the highest contribution came from the downlink band of the base stations, while in only one measurement, the highest contribution originated from the uplink bands of the base stations. All data were subject to the Anderson-Darling test, confirming the generalized extreme value distribution as the best fit for both B and RF-EMF measurements. Additionally, the study assessed B levels inside and outside the bus during charging, revealing heightened readings near the pantograph. These findings significantly contribute to our understanding of electromagnetic field exposure in electric bus environments, highlighting potential health implications and informing the development of targeted mitigation strategies.

SensorsVol. 24(17)
University of Ulster (GB), Inonu University (TR), Ondokuz Mayıs University (TR), Istanbul Metropolitan Municipality (TR), Public Works (GB)
Openalex Percentile: Top 10%
Electromagnetic Fields and Biological Effects
2.65
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.