Investigating the Impact of Ground-Return Parameters on Transitional Voltages at Switching-Off Unloaded Power Transmission Lines

The electrical parameters calculations of the overhead transmission lines are very important to the areas concerned to electromagnetic compatibility and transitional processes in power systems. Therefore, accurate calculations of these parameters were performed in this research, taking into account the ground-return parameters (Carson correction factors). The return parameters of the homogenous ground (one-layered ground) the overhead transmission line passes over were taken into consideration via using the actual value of the ground resistivity. In this research, the effect of ground-return parameters on transitional voltages at switching-off an unloaded transmission line using SF6 circuit-breaker was recorded and clarified. As a result, when the ground-return parameters are taken into account, the overall transmission line inductance increases. This has an obvious impact on the rate of rise of recovery voltage for the SF6 circuit-breaker inter-contact space, that consequently affects the transitional voltages during switching-off process.

Authors

Institutions

Publication Details

Journal
Engineering and Technology Journal
Published
2024-08-30
DOI
https://doi.org/10.47191/etj/v9i08.17
Primary Topic
Lightning and Electromagnetic Phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigating the Impact of Ground-Return Parameters on Transitional Voltages at Switching-Off Unloaded Power Transmission Lines

E. Saafan
Engineering and Technology Journal
Lightning and Electromagnetic Phenomena
article

Investigating the Impact of Ground-Return Parameters on Transitional Voltages at Switching-Off Unloaded Power Transmission Lines

E. Saafan
article en

Abstract

The electrical parameters calculations of the overhead transmission lines are very important to the areas concerned to electromagnetic compatibility and transitional processes in power systems. Therefore, accurate calculations of these parameters were performed in this research, taking into account the ground-return parameters (Carson correction factors). The return parameters of the homogenous ground (one-layered ground) the overhead transmission line passes over were taken into consideration via using the actual value of the ground resistivity. In this research, the effect of ground-return parameters on transitional voltages at switching-off an unloaded transmission line using SF6 circuit-breaker was recorded and clarified. As a result, when the ground-return parameters are taken into account, the overall transmission line inductance increases. This has an obvious impact on the rate of rise of recovery voltage for the SF6 circuit-breaker inter-contact space, that consequently affects the transitional voltages during switching-off process.

Engineering and Technology JournalVol. 09(08)
Mansoura University (EG)
Affordable and clean energy
Openalex Percentile: Top 89%
Lightning and Electromagnetic Phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Investigating the Impact of Ground-Return Parameters on Transitional Voltages at Switching-Off Unloaded Power Transmission Lines — E. Saafan · Engineering and Technology Journal (2024) | TGRS Research Map | TGRS