Multi-Objective Optimization of Building Design Parameters for Cost Reduction and CO2 Emission Control Using Four Different Algorithms

Thermal insulation applications on the exterior facades of buildings have been the subject of numerous studies from the past to the present. Some of these studies focus on the cost reduction effect of insulation, while others emphasize its ecological benefits. In this study, multi-objective optimization, the objectives of which are minimum cost and minimum CO2 emission, has been carried out with the NSGA-II method. In emission calculations, in addition to fuel-related emissions, the carbon footprint of all materials comprising the wall has also been included. The multi-objective optimization study examined four design variables: wall thickness, wall material (light concrete, reinforced concrete, and brick), insulation material (expanded polystyrene, extruded polystyrene, mineral wool, and polyurethane foam), and heating source (natural gas, electricity, fuel oil). Analyses have been carried out for four cities (Osmaniye, Bursa, Isparta, and Erzurum), which are located in different climatic regions, and considering solar radiation effects. An existing building has been taken as the base case scenario, and the study has determined the improvements in the total cost and the amount of CO2 released into the environment when the appropriate insulation material, insulation thickness, wall material, and heating source identified in the multi-objective optimization study have been used. At the cost-oriented optimum point in the study, the most suitable insulation material was found to be expanded polystyrene, the most suitable wall material was brick, and the most suitable heating source was natural gas. In the CO2-oriented optimum, in contrast to the cost-oriented approach, optimal results have been obtained when light concrete was selected as the wall material.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2024-08-30
DOI
https://doi.org/10.3390/app14177668
Citations
15
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
3.98
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multi-Objective Optimization of Building Design Parameters for Cost Reduction and CO2 Emission Control Using Four Different Algorithms

Ahmet Serhan Canbolat, Emre İsa Albak
15 citations
Applied Sciences
Building Energy and Comfort Optimization
3.98
article

Multi-Objective Optimization of Building Design Parameters for Cost Reduction and CO2 Emission Control Using Four Different Algorithms

Ahmet Serhan Canbolat, Emre İsa Albak
article en
15 citations

Abstract

Thermal insulation applications on the exterior facades of buildings have been the subject of numerous studies from the past to the present. Some of these studies focus on the cost reduction effect of insulation, while others emphasize its ecological benefits. In this study, multi-objective optimization, the objectives of which are minimum cost and minimum CO2 emission, has been carried out with the NSGA-II method. In emission calculations, in addition to fuel-related emissions, the carbon footprint of all materials comprising the wall has also been included. The multi-objective optimization study examined four design variables: wall thickness, wall material (light concrete, reinforced concrete, and brick), insulation material (expanded polystyrene, extruded polystyrene, mineral wool, and polyurethane foam), and heating source (natural gas, electricity, fuel oil). Analyses have been carried out for four cities (Osmaniye, Bursa, Isparta, and Erzurum), which are located in different climatic regions, and considering solar radiation effects. An existing building has been taken as the base case scenario, and the study has determined the improvements in the total cost and the amount of CO2 released into the environment when the appropriate insulation material, insulation thickness, wall material, and heating source identified in the multi-objective optimization study have been used. At the cost-oriented optimum point in the study, the most suitable insulation material was found to be expanded polystyrene, the most suitable wall material was brick, and the most suitable heating source was natural gas. In the CO2-oriented optimum, in contrast to the cost-oriented approach, optimal results have been obtained when light concrete was selected as the wall material.

Applied SciencesVol. 14(17)
Bursa Uludağ Üni̇versi̇tesi̇ (TR)
Openalex Percentile: Top 6%
Building Energy and Comfort Optimization
3.98
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.