Second-Life Assessment of Commercial LiFePO4 Batteries Retired from EVs

LiFePO4 (LFP) batteries are well known for their long cycle life. However, there are many reports of significant capacity degradation in LFP battery packs after only three to five years of operation. This study assesses the second-life potential of commercial LFP batteries retired from electric vehicles (EVs) by evaluating their aging characteristics at the cell and module levels. Four LFP cells and four modules were subjected to aging tests under various conditions. The results indicate that LFP cells exhibit long life cycles with gradual capacity degradation and a minimal internal resistance increase. Module-level analysis reveals significant balance issues impacting capacity recovery. Incremental capacity analysis (ICA) and post-mortem analysis identify the loss of active materials and lithium inventory as key aging mechanisms. This study provides the optimal working conditions of second-life LFP batteries and suggests that, with proper balancing systems, LFP batteries can achieve extended second-life use in stationary energy storage applications, emphasizing the importance of effective balance management for sustainable battery utilization.

Authors

Institutions

Publication Details

Journal
Batteries
Published
2024-08-30
DOI
https://doi.org/10.3390/batteries10090306
Citations
13
Primary Topic
Advanced Battery Technologies Research
Type
article
Field-Weighted Citation Impact
2.64

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Second-Life Assessment of Commercial LiFePO4 Batteries Retired from EVs

Zhi Cao, Jing Gu, Naser Vosoughi Kurdkandi, Wei Gao et al.
13 citations
Batteries
Advanced Battery Technologies Research
2.64
article

Second-Life Assessment of Commercial LiFePO4 Batteries Retired from EVs

Zhi Cao, Jing Gu, Naser Vosoughi Kurdkandi, Wei Gao, Chris Mı, Christopher Turchiano, Yuhong Fu
article en
13 citations

Abstract

LiFePO4 (LFP) batteries are well known for their long cycle life. However, there are many reports of significant capacity degradation in LFP battery packs after only three to five years of operation. This study assesses the second-life potential of commercial LFP batteries retired from electric vehicles (EVs) by evaluating their aging characteristics at the cell and module levels. Four LFP cells and four modules were subjected to aging tests under various conditions. The results indicate that LFP cells exhibit long life cycles with gradual capacity degradation and a minimal internal resistance increase. Module-level analysis reveals significant balance issues impacting capacity recovery. Incremental capacity analysis (ICA) and post-mortem analysis identify the loss of active materials and lithium inventory as key aging mechanisms. This study provides the optimal working conditions of second-life LFP batteries and suggests that, with proper balancing systems, LFP batteries can achieve extended second-life use in stationary energy storage applications, emphasizing the importance of effective balance management for sustainable battery utilization.

BatteriesVol. 10(9)
San Diego State University (US)
California Energy Commission
Responsible consumption and production
Openalex Percentile: Top 10%
Advanced Battery Technologies Research
2.64
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.