Vessel recovery using ultrasound localisation microscopy: An in silico comparative study between minimum variance and delay-and-sum beamformers

The use of particle localisation and tracking algorithms on Contrast Enhanced Ultrasound (CEUS) or other ultrasound mode image data containing sparse microbubble (MB) populations, can produce super-resolved vascularization maps. Typically such data stem from conventional delay and sum (DAS) beamforming that is used widely in ultrasound imaging modes. Recently, adaptive beamforming has shown significant improvement in spatial resolution, but its value to super-resolution image analysis approaches is not fully understood. The in silico study here evaluates the performance of combining minimum variance beamformers (MV BF), established to provide improved lateral resolution, compared to DAS BFs with single particle detection. The isolated effect of a range of simplified image-affecting factors such as flow profile, pulse length, noise, vessel separations and data availability is considered. The study aims to assess the vessel recovery performance using the different beamformers and investigate the link with MB detection and localisation. The MV BF was shown to provide improved microvessel position accuracy compared to conventional DAS BFs. In particular, vessel separations between 0.3-4 λ provided superior localisation uncertainty with the MV. In addition, for a separation of 0.36λ, vessel recovery was achieved with both methods but the use of MV eliminated artifacts that appear as additional vessels. These results were found to be linked to improved MB detection and localisation for the MV BF, which is proposed as suitable for testing in Ultrasound Localisation Microscopy (ULM) imaging using patient data.

Authors

Institutions

Publication Details

Journal
Ultrasonics
Published
2024-08-30
DOI
https://doi.org/10.1016/j.ultras.2024.107451
Citations
4
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
1.62

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Vessel recovery using ultrasound localisation microscopy: An in silico comparative study between minimum variance and delay-and-sum beamformers

Barbara Nicolas, Mairead Butler, Γεώργιος Παπαγεωργίου, Weiping Lu et al.
4 citations
Ultrasonics
Ultrasound Imaging and Elastography
1.62
article

Vessel recovery using ultrasound localisation microscopy: An in silico comparative study between minimum variance and delay-and-sum beamformers

Barbara Nicolas, Mairead Butler, Γεώργιος Παπαγεωργίου, Weiping Lu, Lachlan Arthur, Konstantinos Diamantis, Vasiliki Voulgaridou, Vassilis Sboros, Evangelos Kanoulas, Steven Robert McDougall
article en
4 citations

Abstract

The use of particle localisation and tracking algorithms on Contrast Enhanced Ultrasound (CEUS) or other ultrasound mode image data containing sparse microbubble (MB) populations, can produce super-resolved vascularization maps. Typically such data stem from conventional delay and sum (DAS) beamforming that is used widely in ultrasound imaging modes. Recently, adaptive beamforming has shown significant improvement in spatial resolution, but its value to super-resolution image analysis approaches is not fully understood. The in silico study here evaluates the performance of combining minimum variance beamformers (MV BF), established to provide improved lateral resolution, compared to DAS BFs with single particle detection. The isolated effect of a range of simplified image-affecting factors such as flow profile, pulse length, noise, vessel separations and data availability is considered. The study aims to assess the vessel recovery performance using the different beamformers and investigate the link with MB detection and localisation. The MV BF was shown to provide improved microvessel position accuracy compared to conventional DAS BFs. In particular, vessel separations between 0.3-4 λ provided superior localisation uncertainty with the MV. In addition, for a separation of 0.36λ, vessel recovery was achieved with both methods but the use of MV eliminated artifacts that appear as additional vessels. These results were found to be linked to improved MB detection and localisation for the MV BF, which is proposed as suitable for testing in Ultrasound Localisation Microscopy (ULM) imaging using patient data.

UltrasonicsVol. 145
Université Claude Bernard Lyon 1 (FR), Centre National de la Recherche Scientifique (FR), Inserm (FR), Lyon College (US), Heriot-Watt University (GB), Heriot-Watt University Malaysia (MY), Janssen (United Kingdom) (GB), Queen's Medical Centre (GB), Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé (FR), Centre for Inflammation Research (GB), Institut National des Sciences Appliquées de Lyon (FR), University of Edinburgh (GB)
Heriot-Watt University, Engineering and Physical Sciences Research Council, Science and Technology Facilities Council
Life below water
Openalex Percentile: Top 16%
Ultrasound Imaging and Elastography
1.62
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.