Minimal influenza virus transmission from touching contaminated face masks: a laboratory study
The risk of virus transmission via the touching of contaminated masks has long been assumed by infection control teams. Yet, robust evidence to support this belief has been lacking. This risk was investigated in a laboratory setting by measuring the amount of viable influenza virus successfully transferred from artificially contaminated medical (surgical) mask surfaces to a human finger used to swipe their outer surface under various experimental conditions. Despite being exposed to high levels of virus contamination on the masks, very little or no viable virus was successfully transferred from the mask to the finger in these experiments.
Authors
- Masahiro Kohzuki (ORCID: https://orcid.org/0000-0002-7120-2641)
- Yuxuan Fan
- Satoru Ebihara (ORCID: https://orcid.org/0000-0002-3574-649X)
- Julian W. Tang (ORCID: https://orcid.org/0000-0002-4963-1028)
- Hidekazu Nishimura (ORCID: https://orcid.org/0000-0003-1962-2646)
- Yasuhiro Okada
- Soichiro Sakata
Institutions
- Tongji University (CN)
- University of Leicester (GB)
- Tohoku University (JP)
- Kao Corporation (Japan) (JP)
- University Hospitals of Leicester NHS Trust (GB)
- Sendai Medical Center (JP)
- National Hospital Organization (JP)
- Yamagata Prefectural University of Health Sciences (JP)
Publication Details
- Journal
- Scientific Reports
- Published
- 2024-08-30
- DOI
- https://doi.org/10.1038/s41598-024-70615-z
- Citations
- 2
- Primary Topic
- Infection Control and Ventilation
- Type
- article
- Field-Weighted Citation Impact
- 0.84