A Test of Reliability: Cranial Rhythmic Impulse for Distant Diagnoses

Context The osteopathic cranial field suggests that cranial rhythmic impulse (CRI) can be used to examine distal segments. However, there is a lack of research on the reliability of using CRI to diagnose other distal segments. This study aims to evaluate the effectiveness of using the cranial vault hold compared to traditional osteopathic diagnostic techniques to diagnose somatic dysfunctions at the following segments: atlantooccipital joint (OA), atlantoaxial joint (AA), cervical-4 (C4), cervical-7 (C7), thoracic-6 (T6), thoracic-12 (T12), lumbar-3 (L3), sacrum, left innominate, right fibular head, and left radial head. Objective To determine if palpation of CRI can reliably detect somatic dysfunctions in multiple distal segments. Methods The study compared osteopathic physicians' diagnoses of specific segments (OA, AA, C4, C7, T6, T12, L3, sacrum, left innominate, right fibular head, and left radial head) using the cranial vault hold and direct palpation. Two osteopathic neuromusculoskeletal medicine experts (cranial group) diagnosed distal segments via the cranial vault hold, while board-certified osteopathic physicians (confirmatory group) used direct palpation. We recruited 44 second-year osteopathic medical students and osteopathic physicians via a school-wide email. Each participant lay supine on a massage table for diagnosis. A neuromusculoskeletal expert, with a scribe, diagnosed the segments using the cranial vault hold. The process was repeated by a second neuromusculoskeletal expert with another scribe. Two osteopathic physicians then diagnosed the same subjects using direct palpatory techniques. Both osteopathic physicians had to agree on a diagnosis for the segment, or it was excluded from comparison. Cohen's kappa coefficient measured inter-rater reliability between the cranial and confirmatory groups. Results Cranial physician 1 provided all 484 diagnoses, while cranial physician 2 provided 152. Cranial physician 1 showed positive agreement with the confirmatory group (κ>0) in 2/11 (18.2%) segments: T12 and left innominate (κ=0.009 and 0.007). Cranial physician 2 showed positive agreement (κ>0) in 4/11 (36.4%) segments: OA, AA, C4, and left innominate (κ=0.050, 0.031, 0.130, and 0.154). Inter-rater reliability between cranial physicians showed positive agreement in 6/11 (54.5%) segments: OA, AA, C4, sacrum, left innominate, and right fibular head (κ=0.125, 0.022, 0.048, 0.036, 0.154, and 0.0261). Conclusion The positive kappa values, all between 0 and 0.2, indicate the inter-rater reliability for diagnosis with the vault hold is above random chance but has none to slight reliability. The kappa coefficients comparing both cranial physicians indicate positive agreement in six segments, supporting palpation of the same phenomena in six out of 11 (54.5%) segments. However, none of the positive kappa values were statistically significant (p>0.05) and the effect sizes were small, likely due to shared bias among the evaluators. We conclude our experiment suggests palpation of the cranium may not reliably diagnose distal segments. However, our experiment may support a connection between CRI and distal segment somatic dysfunctions. Considering diagnoses of certain segments are above random chance, more research is needed to confirm whether there is a connection between palpation of the CRI and the diagnosis of a distal somatic dysfunction.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2024-08-30
DOI
https://doi.org/10.7759/cureus.68219
Citations
1
Primary Topic
Psychosomatic Disorders and Their Treatments
Type
article
Field-Weighted Citation Impact
0.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Test of Reliability: Cranial Rhythmic Impulse for Distant Diagnoses

Thomas Alexander Quinn, Andrew C Cook, Shannon South, Steven Ma et al.
1 citations
Cureus
Psychosomatic Disorders and Their Treatments
0.39
article

A Test of Reliability: Cranial Rhythmic Impulse for Distant Diagnoses

Thomas Alexander Quinn, Andrew C Cook, Shannon South, Steven Ma, David Boesler, Luis Álvarez, Kevin Thomas, Connor Sweeney, Nicole E. Myers, Madison R Walter
article en
1 citations

Abstract

Context The osteopathic cranial field suggests that cranial rhythmic impulse (CRI) can be used to examine distal segments. However, there is a lack of research on the reliability of using CRI to diagnose other distal segments. This study aims to evaluate the effectiveness of using the cranial vault hold compared to traditional osteopathic diagnostic techniques to diagnose somatic dysfunctions at the following segments: atlantooccipital joint (OA), atlantoaxial joint (AA), cervical-4 (C4), cervical-7 (C7), thoracic-6 (T6), thoracic-12 (T12), lumbar-3 (L3), sacrum, left innominate, right fibular head, and left radial head. Objective To determine if palpation of CRI can reliably detect somatic dysfunctions in multiple distal segments. Methods The study compared osteopathic physicians' diagnoses of specific segments (OA, AA, C4, C7, T6, T12, L3, sacrum, left innominate, right fibular head, and left radial head) using the cranial vault hold and direct palpation. Two osteopathic neuromusculoskeletal medicine experts (cranial group) diagnosed distal segments via the cranial vault hold, while board-certified osteopathic physicians (confirmatory group) used direct palpation. We recruited 44 second-year osteopathic medical students and osteopathic physicians via a school-wide email. Each participant lay supine on a massage table for diagnosis. A neuromusculoskeletal expert, with a scribe, diagnosed the segments using the cranial vault hold. The process was repeated by a second neuromusculoskeletal expert with another scribe. Two osteopathic physicians then diagnosed the same subjects using direct palpatory techniques. Both osteopathic physicians had to agree on a diagnosis for the segment, or it was excluded from comparison. Cohen's kappa coefficient measured inter-rater reliability between the cranial and confirmatory groups. Results Cranial physician 1 provided all 484 diagnoses, while cranial physician 2 provided 152. Cranial physician 1 showed positive agreement with the confirmatory group (κ>0) in 2/11 (18.2%) segments: T12 and left innominate (κ=0.009 and 0.007). Cranial physician 2 showed positive agreement (κ>0) in 4/11 (36.4%) segments: OA, AA, C4, and left innominate (κ=0.050, 0.031, 0.130, and 0.154). Inter-rater reliability between cranial physicians showed positive agreement in 6/11 (54.5%) segments: OA, AA, C4, sacrum, left innominate, and right fibular head (κ=0.125, 0.022, 0.048, 0.036, 0.154, and 0.0261). Conclusion The positive kappa values, all between 0 and 0.2, indicate the inter-rater reliability for diagnosis with the vault hold is above random chance but has none to slight reliability. The kappa coefficients comparing both cranial physicians indicate positive agreement in six segments, supporting palpation of the same phenomena in six out of 11 (54.5%) segments. However, none of the positive kappa values were statistically significant (p>0.05) and the effect sizes were small, likely due to shared bias among the evaluators. We conclude our experiment suggests palpation of the cranium may not reliably diagnose distal segments. However, our experiment may support a connection between CRI and distal segment somatic dysfunctions. Considering diagnoses of certain segments are above random chance, more research is needed to confirm whether there is a connection between palpation of the CRI and the diagnosis of a distal somatic dysfunction.

CureusVol. 16(8)
Lake Erie College of Osteopathic Medicine (US)
Openalex Percentile: Top 36%
Psychosomatic Disorders and Their Treatments
0.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.