Reliability of Digital Artery Palpation and Pulse Oximetry Waveform As Alternatives to Radial Pulse in the Assessment of Upper Limb Injuries

Digital pulse palpation can be used as a surrogate method of assessing hand perfusion. When present, it can be assumed a radial pulse is present due to a high positive predictive value and no false positives seen in any participant. When absent, further investigation is required. The PO waveform was found to be more sensitive than digital or radial pulse palpation as a measure of distal perfusion, with a return of waveform prior to palpable pulses. This likely represents a more accurate clinical test of distal perfusion and can be relied upon even when pulses are not palpable.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2024-08-30
DOI
https://doi.org/10.7759/cureus.68224
Primary Topic
Traumatic Ocular and Foreign Body Injuries
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reliability of Digital Artery Palpation and Pulse Oximetry Waveform As Alternatives to Radial Pulse in the Assessment of Upper Limb Injuries

M Coombe-Jones, Matthew Lea, Ahmed Elmahdi, Edward Gee et al.
Cureus
Traumatic Ocular and Foreign Body Injuries
article

Reliability of Digital Artery Palpation and Pulse Oximetry Waveform As Alternatives to Radial Pulse in the Assessment of Upper Limb Injuries

M Coombe-Jones, Matthew Lea, Ahmed Elmahdi, Edward Gee, Amol Chitre, Sammie-Jo Arnold
article en

Abstract

Digital pulse palpation can be used as a surrogate method of assessing hand perfusion. When present, it can be assumed a radial pulse is present due to a high positive predictive value and no false positives seen in any participant. When absent, further investigation is required. The PO waveform was found to be more sensitive than digital or radial pulse palpation as a measure of distal perfusion, with a return of waveform prior to palpable pulses. This likely represents a more accurate clinical test of distal perfusion and can be relied upon even when pulses are not palpable.

CureusVol. 16(8)
Lancashire Teaching Hospitals NHS Foundation Trust (GB), Nottingham University Hospitals NHS Trust (GB), Salford Royal NHS Foundation Trust (GB), East Lancashire Hospitals NHS Trust (GB)
Good health and well-being
Openalex Percentile: Top 75%
Traumatic Ocular and Foreign Body Injuries
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.