Assessing the impact of cold plasma rotational dynamics on ginger's total phenolic content, antioxidant activity, surface structure and color using response surface methodology

This study investigated the efficacy of a rotational chamber in enhancing the effectiveness of cold plasma application to augment antioxidant activity and phenolic content in ginger ( Zingiber officinale ). To address the limitation of cold plasma (CP), which predominantly treats only the surface layers of samples, we implemented rotational techniques during the treatment. This methodology facilitates a more uniform treatment, ensuring that all layers of the samples are effectively exposed to plasma. We employed response surface methodology (RSM) to analyze the effects of three variables: power (10–90 W), treatment time (1–30 min), and pressure (0.4–0.9 mbar), along with a categorical variable for rotation. CP treatment (65 W, 0.7 mbar, 1 min with rotation) resulted in a significant increase in antioxidant activity compared to non-treated samples, determined by 2,2-diphenyl-1-picrylhydrazyl (DPPH), ferric-reducing antioxidant power (FRAP), and 2,2′-azino-bis(3-ethylbenzothiazoline-6-sulphonic acid) ABTS assays, and total phenolic content reaching their highest values of 100.9 Trolox equivalent (TE) μmol⋅L −1 , 8.23 Fe 2+ ⋅g −1 , 0.293 μmol⋅g −1 , and 32.80 gallic acid equivalent (GAE)/g, respectively. There were no significant changes in color. Scanning Electron Microscopy (SEM) analysis revealed that the samples treated with CP exhibited a smoother surface, albeit with minimal damage to cell walls in our selected samples. Including a rotational feature as a unique upgrade to the cold plasma, the glow discharge device demonstrated positive enhancements and preservation of antioxidant activity and phenolic compounds. • Rotary low-pressure cold plasma performed effectively. • Rotary low-pressure cold plasma increased the antioxidant activity. • Rotary low-pressure cold plasma increased phenolic compounds. • The sample's surface became smoother after minimal cold plasma treatment.

Authors

Institutions

Publication Details

Journal
LWT
Published
2024-08-30
DOI
https://doi.org/10.1016/j.lwt.2024.116682
Citations
15
Primary Topic
Ginger and Zingiberaceae research
Type
article
Field-Weighted Citation Impact
7.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing the impact of cold plasma rotational dynamics on ginger's total phenolic content, antioxidant activity, surface structure and color using response surface methodology

Tuba Esatbeyoglu, Sina Zargarchi
15 citations
LWT
Ginger and Zingiberaceae research
7.00
article

Assessing the impact of cold plasma rotational dynamics on ginger's total phenolic content, antioxidant activity, surface structure and color using response surface methodology

Tuba Esatbeyoglu, Sina Zargarchi
article en
15 citations

Abstract

This study investigated the efficacy of a rotational chamber in enhancing the effectiveness of cold plasma application to augment antioxidant activity and phenolic content in ginger ( Zingiber officinale ). To address the limitation of cold plasma (CP), which predominantly treats only the surface layers of samples, we implemented rotational techniques during the treatment. This methodology facilitates a more uniform treatment, ensuring that all layers of the samples are effectively exposed to plasma. We employed response surface methodology (RSM) to analyze the effects of three variables: power (10–90 W), treatment time (1–30 min), and pressure (0.4–0.9 mbar), along with a categorical variable for rotation. CP treatment (65 W, 0.7 mbar, 1 min with rotation) resulted in a significant increase in antioxidant activity compared to non-treated samples, determined by 2,2-diphenyl-1-picrylhydrazyl (DPPH), ferric-reducing antioxidant power (FRAP), and 2,2′-azino-bis(3-ethylbenzothiazoline-6-sulphonic acid) ABTS assays, and total phenolic content reaching their highest values of 100.9 Trolox equivalent (TE) μmol⋅L −1 , 8.23 Fe 2+ ⋅g −1 , 0.293 μmol⋅g −1 , and 32.80 gallic acid equivalent (GAE)/g, respectively. There were no significant changes in color. Scanning Electron Microscopy (SEM) analysis revealed that the samples treated with CP exhibited a smoother surface, albeit with minimal damage to cell walls in our selected samples. Including a rotational feature as a unique upgrade to the cold plasma, the glow discharge device demonstrated positive enhancements and preservation of antioxidant activity and phenolic compounds. • Rotary low-pressure cold plasma performed effectively. • Rotary low-pressure cold plasma increased the antioxidant activity. • Rotary low-pressure cold plasma increased phenolic compounds. • The sample's surface became smoother after minimal cold plasma treatment.

LWTVol. 208
Leibniz University Hannover (DE)
Konrad-Adenauer-Stiftung
Zero hunger
Openalex Percentile: Top 2%
Ginger and Zingiberaceae research
7.00
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Assessing the impact of cold plasma rotational dynamics on ginger's total phenolic content, antioxidant activity, surface structure and color using response surface methodology — Tuba Esatbeyoglu, Sina Zargarchi · LWT (2024) | TGRS Research Map | TGRS