Comparison of a hand-held high-end resolution infrared thermography (FLIR P640) and a smartphone infrared thermographic device (FLIR One) for the assessment of skin surface temperature after anaesthetising the median nerve in Healthy horses

Accuracy of a median nerve block is normally assessed by testing skin sensitivity on the medial and dorsal aspects of fetlock and pastern. The present study evaluated subjective and objective analysis of skin surface temperature obtained with two different infrared (IR) thermography cameras (a high-end [FLIR P640] and a smartphone IR thermography device [FLIR One®]) before and after anaesthesia of the median nerve. Thermographic images were obtained at 0, 30, 60 and 90 minutes after performing a median nerve block with 2% mepivacaine hydrochloride. The subjective analysis of thermographic images using the FLIR P640 camera found assessors had >50% agreement for the presence of a nerve block (p<0.01) based on assessment of skin temperature within the expected dermatome of the median nerve. The objective analysis found skin temperature increases in the treated leg using the FLIR One® in the dorsal fetlock, dorsal pastern and medial pastern at 60 minutes, and the lateral pastern at 90 minutes (p<0.05). The treated leg, imaged using the FLIR P640 camera, had increases in skin temperature at the medial aspect of the fetlock at 60 minutes and lateral pastern at 90 minutes (p<0.05). Images obtained with the P640 camera had higher resolution and finer thermal detail. The images obtained with the FLIR One® camera had a wider temperature range with overall higher temperature measurements than the images obtained using the P640 camera (p<0.001). Skin temperatures in horses should be interpreted with caution when using the FLIR One® camera. Furthermore, the FLIR One® device detected an increase in skin surface temperature in both treated and non-treated legs and should not be used for assessment of a median nerve block. Infrared thermography appears to be useful for determining the presence of a high regional nerve block such as the median nerve block by observing increased temperatures of the skin surface after perineural anaesthesia. Further studies with a larger sample size as well as investigating the use of thermography for assessment of other regional nerve blocks are warranted.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2024-08-30
DOI
https://doi.org/10.1371/journal.pone.0309603
Citations
4
Primary Topic
Infrared Thermography in Medicine
Type
article
Field-Weighted Citation Impact
1.62
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of a hand-held high-end resolution infrared thermography (FLIR P640) and a smartphone infrared thermographic device (FLIR One) for the assessment of skin surface temperature after anaesthetising the median nerve in Healthy horses

Luiz Santos, Kellie Adamson, John Schumacher, Leah McGlinchey et al.
4 citations
PLoS ONE
Infrared Thermography in Medicine
1.62
article

Comparison of a hand-held high-end resolution infrared thermography (FLIR P640) and a smartphone infrared thermographic device (FLIR One) for the assessment of skin surface temperature after anaesthetising the median nerve in Healthy horses

Luiz Santos, Kellie Adamson, John Schumacher, Leah McGlinchey, Olena Kravchuk, Gustavo Ferlini Agne
article en
4 citations

Abstract

Accuracy of a median nerve block is normally assessed by testing skin sensitivity on the medial and dorsal aspects of fetlock and pastern. The present study evaluated subjective and objective analysis of skin surface temperature obtained with two different infrared (IR) thermography cameras (a high-end [FLIR P640] and a smartphone IR thermography device [FLIR One®]) before and after anaesthesia of the median nerve. Thermographic images were obtained at 0, 30, 60 and 90 minutes after performing a median nerve block with 2% mepivacaine hydrochloride. The subjective analysis of thermographic images using the FLIR P640 camera found assessors had >50% agreement for the presence of a nerve block (p<0.01) based on assessment of skin temperature within the expected dermatome of the median nerve. The objective analysis found skin temperature increases in the treated leg using the FLIR One® in the dorsal fetlock, dorsal pastern and medial pastern at 60 minutes, and the lateral pastern at 90 minutes (p<0.05). The treated leg, imaged using the FLIR P640 camera, had increases in skin temperature at the medial aspect of the fetlock at 60 minutes and lateral pastern at 90 minutes (p<0.05). Images obtained with the P640 camera had higher resolution and finer thermal detail. The images obtained with the FLIR One® camera had a wider temperature range with overall higher temperature measurements than the images obtained using the P640 camera (p<0.001). Skin temperatures in horses should be interpreted with caution when using the FLIR One® camera. Furthermore, the FLIR One® device detected an increase in skin surface temperature in both treated and non-treated legs and should not be used for assessment of a median nerve block. Infrared thermography appears to be useful for determining the presence of a high regional nerve block such as the median nerve block by observing increased temperatures of the skin surface after perineural anaesthesia. Further studies with a larger sample size as well as investigating the use of thermography for assessment of other regional nerve blocks are warranted.

PLoS ONEVol. 19(8)
The University of Adelaide (AU), University of Glasgow (GB), Auburn University (US)
Openalex Percentile: Top 16%
Infrared Thermography in Medicine
1.62
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.