Heat Typed Fiber Liquid Flow Sensor With Wide Sensing Range and High Sensitivity

In this paper, a heat typed fiber sensor for microfluidic velocity measurement with large sensing range and high sensitivity is demonstrated. The single-mode fiber (SMF) end face and polymer cap form a Fabry Perot (FP) structure. The Au film layer on the surface of the polymer cap is heated by an infrared laser, and the heated Au film layer undergoes heat transfer to the polymer cap structure, causing it to expand upon heating. Due to the heat carried away by the polymer cap structure at the action of microfluidic rates, the cavity length of the polymer cap structure changes. Therefore, the flow rate can be measured by monitoring the wavelength drift of the interference spectrum. The experimental results indicate that the laser can induced heat and transfer to the probe because the Au film has excellent thermal conductivity. Furthermore, the probe has a good response to the flow rate. The probe has advantages of simple preparation, small size, and strong structure, which can be used for micro flow rate sensing with wide sensing range and high sensitivity.

Authors

Institutions

Publication Details

Journal
Journal of Lightwave Technology
Published
2024-08-30
DOI
https://doi.org/10.1109/jlt.2024.3452492
Citations
2
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.42
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Heat Typed Fiber Liquid Flow Sensor With Wide Sensing Range and High Sensitivity

Yi Zhang, Mingxiang Ling, Weijiang Xu, Jian Qu
2 citations
Journal of Lightwave Technology
Advanced Fiber Optic Sensors
0.42
article

Heat Typed Fiber Liquid Flow Sensor With Wide Sensing Range and High Sensitivity

Yi Zhang, Mingxiang Ling, Weijiang Xu, Jian Qu
article en
2 citations

Abstract

In this paper, a heat typed fiber sensor for microfluidic velocity measurement with large sensing range and high sensitivity is demonstrated. The single-mode fiber (SMF) end face and polymer cap form a Fabry Perot (FP) structure. The Au film layer on the surface of the polymer cap is heated by an infrared laser, and the heated Au film layer undergoes heat transfer to the polymer cap structure, causing it to expand upon heating. Due to the heat carried away by the polymer cap structure at the action of microfluidic rates, the cavity length of the polymer cap structure changes. Therefore, the flow rate can be measured by monitoring the wavelength drift of the interference spectrum. The experimental results indicate that the laser can induced heat and transfer to the probe because the Au film has excellent thermal conductivity. Furthermore, the probe has a good response to the flow rate. The probe has advantages of simple preparation, small size, and strong structure, which can be used for micro flow rate sensing with wide sensing range and high sensitivity.

Journal of Lightwave TechnologyVol. 43(1)
Harbin Institute of Technology (CN), Soochow University (CN)
Affordable and clean energy
Openalex Percentile: Top 38%
Advanced Fiber Optic Sensors
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.