Programmable Pulse Generator by Envelope Detection for Implantable Medical Devices

Pulse generators in implantable medical devices need to be programmable and miniaturized. However, the existing designs of pulse generator cannot satisfy both of the requirements at the same time. This paper presents a novel design of pulse generators applying magnetic resonance, which is composed of a class-C inverter and an envelope detector, for implantable medical devices. Through simulation and tests, we verify the superiority of our design in programmability of the output pulse signal and miniaturization of the implants, compared with the conventional designs. The amplitude, frequency and duty cycle of the output pulse signal of the implanted receiver can be modulated by controlling the input signal of the transmitter outside the human body. And the footprint of the implanted receiver can be miniaturized to 12 mm × 14 mm × 5 mm, which is smaller than half the size of most of the existing products.

Authors

Institutions

Publication Details

Journal
IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology
Published
2024-08-30
DOI
https://doi.org/10.1109/jerm.2024.3435075
Citations
1
Primary Topic
Neuroscience and Neural Engineering
Type
article
Field-Weighted Citation Impact
0.27

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Programmable Pulse Generator by Envelope Detection for Implantable Medical Devices

Hao Zhang, Wenlong Zhou, Xiaozhou Zhou
1 citations
IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology
Neuroscience and Neural Engineering
0.27
article

Programmable Pulse Generator by Envelope Detection for Implantable Medical Devices

Hao Zhang, Wenlong Zhou, Xiaozhou Zhou
article en
1 citations

Abstract

Pulse generators in implantable medical devices need to be programmable and miniaturized. However, the existing designs of pulse generator cannot satisfy both of the requirements at the same time. This paper presents a novel design of pulse generators applying magnetic resonance, which is composed of a class-C inverter and an envelope detector, for implantable medical devices. Through simulation and tests, we verify the superiority of our design in programmability of the output pulse signal and miniaturization of the implants, compared with the conventional designs. The amplitude, frequency and duty cycle of the output pulse signal of the implanted receiver can be modulated by controlling the input signal of the transmitter outside the human body. And the footprint of the implanted receiver can be miniaturized to 12 mm × 14 mm × 5 mm, which is smaller than half the size of most of the existing products.

IEEE Journal of Electromagnetics RF and Microwaves in Medicine and BiologyVol. 9(1)
Northwestern Polytechnical University (CN)
Key Research and Development Projects of Shaanxi Province
Openalex Percentile: Top 45%
Neuroscience and Neural Engineering
0.27
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Programmable Pulse Generator by Envelope Detection for Implantable Medical Devices — Hao Zhang, Wenlong Zhou, et al. · IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology (2024) | TGRS Research Map | TGRS