Parametric Amplification in Depletion Layer Transduced Microelectromechanical Resonator

This paper introduces a method for signal amplification and enhancement of full width half maxima (FWHM) in a depletion layer-transduced flexural resonator using the parametric effect. The device can be used as a filter-amplifier, or as a low-noise readout method for sensors. Parametric excitation shows a significant drop in device impedance, from 334.2 k<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\Omega $ </tex-math></inline-formula> without a pump signal to 45.9 k<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\Omega $ </tex-math></inline-formula> with a 300 mV pump signal. In the absence of the pump signal, with an input power of −10 dBm, the resonator produces an output power of −44.87 dBm at ~400 kHz and a FWHM value of 23 Hz. However, when a 200 mV pump signal at <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$2f_{0}$ </tex-math></inline-formula> with <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\pi $ </tex-math></inline-formula>/2 phase shift, is superimposed with the same input power, the resonator’s output power amplifies to −11.49 dBm, and the FWHM value substantially decreases to 10 Hz. This leads to a 33.58 dBm of amplification and 2.3x improvement in Q attributed to the parametric effect. A detailed analytical model of the transducer is presented. [2024-0061]

Authors

Institutions

Publication Details

Journal
Journal of Microelectromechanical Systems
Published
2024-08-30
DOI
https://doi.org/10.1109/jmems.2024.3447694
Primary Topic
Advanced MEMS and NEMS Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Parametric Amplification in Depletion Layer Transduced Microelectromechanical Resonator

Satish K. Verma, Bhaskar Mitra
Journal of Microelectromechanical Systems
Advanced MEMS and NEMS Technologies
article

Parametric Amplification in Depletion Layer Transduced Microelectromechanical Resonator

Satish K. Verma, Bhaskar Mitra
article en

Abstract

This paper introduces a method for signal amplification and enhancement of full width half maxima (FWHM) in a depletion layer-transduced flexural resonator using the parametric effect. The device can be used as a filter-amplifier, or as a low-noise readout method for sensors. Parametric excitation shows a significant drop in device impedance, from 334.2 k<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\Omega $ </tex-math></inline-formula> without a pump signal to 45.9 k<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\Omega $ </tex-math></inline-formula> with a 300 mV pump signal. In the absence of the pump signal, with an input power of −10 dBm, the resonator produces an output power of −44.87 dBm at ~400 kHz and a FWHM value of 23 Hz. However, when a 200 mV pump signal at <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$2f_{0}$ </tex-math></inline-formula> with <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\pi $ </tex-math></inline-formula>/2 phase shift, is superimposed with the same input power, the resonator’s output power amplifies to −11.49 dBm, and the FWHM value substantially decreases to 10 Hz. This leads to a 33.58 dBm of amplification and 2.3x improvement in Q attributed to the parametric effect. A detailed analytical model of the transducer is presented. [2024-0061]

Journal of Microelectromechanical SystemsVol. 33(6)
Indian Institute of Technology Delhi (IN)
Affordable and clean energy
Openalex Percentile: Top 88%
Advanced MEMS and NEMS Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Parametric Amplification in Depletion Layer Transduced Microelectromechanical Resonator — Satish K. Verma, Bhaskar Mitra · Journal of Microelectromechanical Systems (2024) | TGRS Research Map | TGRS