Advancement in PMN-PT transparent piezoelectric ceramic for photoacoustic/ultrasound dual-mode imaging

Dual-mode imaging combining photoacoustic and ultrasound modalities holds great promise for comprehensive tissue characterization. In traditional dual-mode imaging systems, however, the opaque ultrasound transducers are integrated in complex optical and ultrasound paths, leading to compromises in imaging efficiency and sensitivity. To address these challenges, we design and produce highly transparent Pb(Mg,Nb)O 3 -PbTiO 3 ceramics with exceptional transparency of 68%, alongside a remarkable ultrahigh piezoelectric d 33 of 1500 pC/N. Leveraging this material, we fabricate a high-sensitivity transparent piezoelectric ultrasound transducer (TPUT) with a center frequency of 16 MHz and a bandwidth of 30%, which seamlessly integrating ultrasound and photoacoustic capabilities into one system to achieve simultaneous photoacoustic/ultrasound dual-mode imaging, showcasing a remarkable sensitivity for deep-tissue detection ( e.g. , 7.5 mm thick chicken breast meat). Additionally, in vivo photoacoustic imaging of subcutaneous microvasculature in a mouse ear was successfully achieved via 28 MHz TPUT. Our innovation not only advances imaging performance but also offers a cost-effective solution, paving the way for transformative biomedical imaging applications. • Eu-PMN-PT ceramics with high transparency of 68% and d 33 of 1500 pC/N were produced • The origin of high transparency and d 33 in the ceramic was discussed in detail • High-sensitivity transparent piezoelectric ultrasound transducer was fabricated • Photoacoustic and ultrasound dual-mode imaging of phantom was successfully achieved • A remarkable sensitivity for deep-tissue detection (7.5 mm chicken meat) was found • In vivo photoacoustic imaging of microvasculature in mouse ear was validated

Authors

Institutions

Publication Details

Journal
Journal of Materiomics
Published
2024-08-30
DOI
https://doi.org/10.1016/j.jmat.2024.100932
Citations
16
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
2.95
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Advancement in PMN-PT transparent piezoelectric ceramic for photoacoustic/ultrasound dual-mode imaging

Xiaojing Gong, Xiatian Wang, Kwok Ho Lam, Pengkun Guo et al.
16 citations
Journal of Materiomics
Photoacoustic and Ultrasonic Imaging
2.95
article

Advancement in PMN-PT transparent piezoelectric ceramic for photoacoustic/ultrasound dual-mode imaging

Xiaojing Gong, Xiatian Wang, Kwok Ho Lam, Pengkun Guo, Zhihua Xie, Tianlong Zhao, Yalin Qin, Yongcheng Zhang, Weijie Zheng, Yanan Wang, Jiaming Zhang, Shujun J. Zhang, Gao Wen, Lin Zhu, Riqiang Lin, Feng Li, Jiale Lan
article en
16 citations

Abstract

Dual-mode imaging combining photoacoustic and ultrasound modalities holds great promise for comprehensive tissue characterization. In traditional dual-mode imaging systems, however, the opaque ultrasound transducers are integrated in complex optical and ultrasound paths, leading to compromises in imaging efficiency and sensitivity. To address these challenges, we design and produce highly transparent Pb(Mg,Nb)O 3 -PbTiO 3 ceramics with exceptional transparency of 68%, alongside a remarkable ultrahigh piezoelectric d 33 of 1500 pC/N. Leveraging this material, we fabricate a high-sensitivity transparent piezoelectric ultrasound transducer (TPUT) with a center frequency of 16 MHz and a bandwidth of 30%, which seamlessly integrating ultrasound and photoacoustic capabilities into one system to achieve simultaneous photoacoustic/ultrasound dual-mode imaging, showcasing a remarkable sensitivity for deep-tissue detection ( e.g. , 7.5 mm thick chicken breast meat). Additionally, in vivo photoacoustic imaging of subcutaneous microvasculature in a mouse ear was successfully achieved via 28 MHz TPUT. Our innovation not only advances imaging performance but also offers a cost-effective solution, paving the way for transformative biomedical imaging applications. • Eu-PMN-PT ceramics with high transparency of 68% and d 33 of 1500 pC/N were produced • The origin of high transparency and d 33 in the ceramic was discussed in detail • High-sensitivity transparent piezoelectric ultrasound transducer was fabricated • Photoacoustic and ultrasound dual-mode imaging of phantom was successfully achieved • A remarkable sensitivity for deep-tissue detection (7.5 mm chicken meat) was found • In vivo photoacoustic imaging of microvasculature in mouse ear was validated

Journal of MateriomicsVol. 11(4)
Qingdao University (CN), Hong Kong Polytechnic University (HK), Anhui University (CN), Xidian University (CN), University of Wollongong (AU), Hefei Institutes of Physical Science (CN), Shenzhen Institutes of Advanced Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 9%
Photoacoustic and Ultrasonic Imaging
2.95
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.