Performance analysis of precooling systems for cryogenic carbon capture: A comparative study of theoretical, numerical, and experimental methods
The urgency of addressing climate change has necessitated innovative and practical approaches to reducing greenhouse gas emissions. Cryogenic Carbon Capture (CCC) technology has emerged as a promising solution for capturing CO 2 from industrial emissions. This study investigates a simplified design for a precooling system within CCC technology, focusing on optimizing the efficiency and reliability of the system while minimizing energy consumption. The research examines the effects of CO 2 concentration in a gas mixture (simulated flue gas, nitrogen and carbon dioxide), cooling bath temperature, and gas mixture flow rate on the performance of heat exchangers in the precooling system. Theoretical, numerical, and experimental analyses were conducted to assess the system's performance. The use of liquid nitrogen at −196 °C in the cooling bath was found unsuitable due to CO 2 freezing within the pipes. Instead, a mixture of dry ice and isopropyl alcohol at −78.5 °C proved effective in maintaining consistent temperature and pressure conditions without causing CO 2 blockages. Numerical simulations highlighted the importance of optimizing pipe length to balance temperature control and pressure dynamics, with a 140 cm pipe length identified as optimal for heat exchanger design. Experimental results revealed that longer pipes enhance cooling performance due to increased heat exchange surface area, while higher CO 2 compositions and flow rates result in higher outlet temperatures and pressures. The study emphasizes the need for further research and simulation work to refine heat exchanger designs for industrial applications, aiming to develop systems that maximize cooling efficiency while ensuring reliable operation. • Liquid nitrogen (−196 °C) in CCC cooling baths causes CO 2 freezing and pipe clogging. • Longer pipes enhance cooling efficiency by reducing outlet temperatures due to increased heat exchange surface area. • Higher CO 2 concentrations increase outlet temperatures due to lower thermal diffusivity. • Higher flow rates raise outlet temperatures and pressures. • Optimizing pipe length is important for balancing temperature control and pressure dynamics in efficient heat exchanger design.
Authors
- Yuttana Mona (ORCID: https://orcid.org/0000-0002-1102-9242)
- Niti Kammuang-lue (ORCID: https://orcid.org/0000-0002-4893-3817)
- Phrut Sakulchangsatjatai (ORCID: https://orcid.org/0000-0003-3698-7065)
- Ramnarong Wanison (ORCID: https://orcid.org/0000-0002-5078-9893)
- Pradit Terdtoon
- Nakorn Tippayawong (ORCID: https://orcid.org/0000-0002-6104-7676)
- Pana Suttakul (ORCID: https://orcid.org/0000-0002-2946-8921)
- Tongtrakan Soisuwan
- Pattaramet Sripuangchai
- Panuwat Phermkorn
Institutions
- Chiang Mai University (TH)
Publication Details
- Journal
- Results in Engineering
- Published
- 2024-08-30
- DOI
- https://doi.org/10.1016/j.rineng.2024.102763
- Citations
- 9
- Primary Topic
- Carbon Dioxide Capture Technologies
- Type
- article
- Field-Weighted Citation Impact
- 1.91