Performance analysis of precooling systems for cryogenic carbon capture: A comparative study of theoretical, numerical, and experimental methods

The urgency of addressing climate change has necessitated innovative and practical approaches to reducing greenhouse gas emissions. Cryogenic Carbon Capture (CCC) technology has emerged as a promising solution for capturing CO 2 from industrial emissions. This study investigates a simplified design for a precooling system within CCC technology, focusing on optimizing the efficiency and reliability of the system while minimizing energy consumption. The research examines the effects of CO 2 concentration in a gas mixture (simulated flue gas, nitrogen and carbon dioxide), cooling bath temperature, and gas mixture flow rate on the performance of heat exchangers in the precooling system. Theoretical, numerical, and experimental analyses were conducted to assess the system's performance. The use of liquid nitrogen at −196 °C in the cooling bath was found unsuitable due to CO 2 freezing within the pipes. Instead, a mixture of dry ice and isopropyl alcohol at −78.5 °C proved effective in maintaining consistent temperature and pressure conditions without causing CO 2 blockages. Numerical simulations highlighted the importance of optimizing pipe length to balance temperature control and pressure dynamics, with a 140 cm pipe length identified as optimal for heat exchanger design. Experimental results revealed that longer pipes enhance cooling performance due to increased heat exchange surface area, while higher CO 2 compositions and flow rates result in higher outlet temperatures and pressures. The study emphasizes the need for further research and simulation work to refine heat exchanger designs for industrial applications, aiming to develop systems that maximize cooling efficiency while ensuring reliable operation. • Liquid nitrogen (−196 °C) in CCC cooling baths causes CO 2 freezing and pipe clogging. • Longer pipes enhance cooling efficiency by reducing outlet temperatures due to increased heat exchange surface area. • Higher CO 2 concentrations increase outlet temperatures due to lower thermal diffusivity. • Higher flow rates raise outlet temperatures and pressures. • Optimizing pipe length is important for balancing temperature control and pressure dynamics in efficient heat exchanger design.

Authors

Institutions

Publication Details

Journal
Results in Engineering
Published
2024-08-30
DOI
https://doi.org/10.1016/j.rineng.2024.102763
Citations
9
Primary Topic
Carbon Dioxide Capture Technologies
Type
article
Field-Weighted Citation Impact
1.91
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance analysis of precooling systems for cryogenic carbon capture: A comparative study of theoretical, numerical, and experimental methods

Yuttana Mona, Niti Kammuang-lue, Phrut Sakulchangsatjatai, Ramnarong Wanison et al.
9 citations
Results in Engineering
Carbon Dioxide Capture Technologies
1.91
article

Performance analysis of precooling systems for cryogenic carbon capture: A comparative study of theoretical, numerical, and experimental methods

Yuttana Mona, Niti Kammuang-lue, Phrut Sakulchangsatjatai, Ramnarong Wanison, Pradit Terdtoon, Nakorn Tippayawong, Pana Suttakul, Tongtrakan Soisuwan, Pattaramet Sripuangchai, Panuwat Phermkorn
article en
9 citations

Abstract

The urgency of addressing climate change has necessitated innovative and practical approaches to reducing greenhouse gas emissions. Cryogenic Carbon Capture (CCC) technology has emerged as a promising solution for capturing CO 2 from industrial emissions. This study investigates a simplified design for a precooling system within CCC technology, focusing on optimizing the efficiency and reliability of the system while minimizing energy consumption. The research examines the effects of CO 2 concentration in a gas mixture (simulated flue gas, nitrogen and carbon dioxide), cooling bath temperature, and gas mixture flow rate on the performance of heat exchangers in the precooling system. Theoretical, numerical, and experimental analyses were conducted to assess the system's performance. The use of liquid nitrogen at −196 °C in the cooling bath was found unsuitable due to CO 2 freezing within the pipes. Instead, a mixture of dry ice and isopropyl alcohol at −78.5 °C proved effective in maintaining consistent temperature and pressure conditions without causing CO 2 blockages. Numerical simulations highlighted the importance of optimizing pipe length to balance temperature control and pressure dynamics, with a 140 cm pipe length identified as optimal for heat exchanger design. Experimental results revealed that longer pipes enhance cooling performance due to increased heat exchange surface area, while higher CO 2 compositions and flow rates result in higher outlet temperatures and pressures. The study emphasizes the need for further research and simulation work to refine heat exchanger designs for industrial applications, aiming to develop systems that maximize cooling efficiency while ensuring reliable operation. • Liquid nitrogen (−196 °C) in CCC cooling baths causes CO 2 freezing and pipe clogging. • Longer pipes enhance cooling efficiency by reducing outlet temperatures due to increased heat exchange surface area. • Higher CO 2 concentrations increase outlet temperatures due to lower thermal diffusivity. • Higher flow rates raise outlet temperatures and pressures. • Optimizing pipe length is important for balancing temperature control and pressure dynamics in efficient heat exchanger design.

Results in EngineeringVol. 23
Chiang Mai University (TH)
Openalex Percentile: Top 15%
Carbon Dioxide Capture Technologies
1.91
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.