Highly sensitive protection scheme considering the PV operation control models

• A new protection methodology based on current-voltage characteristics. • Optimal OCR coordination under smart inverter control strategies. • Comparative analysis through the influence of diverse control techniques. The integration of distributed generation (DG) based on inverters into power systems has increased significantly, necessitating a thorough understanding of its impact on fault analysis and the performance of distribution networks' protection mechanisms. This study addresses this issue by examining how various inverter management modes influence protective relay systems within IEEE 9-bus redial and mesh networks, CIGRE and IEEE 33-bus networks featuring Photovoltaic (PV) farms and Battery Energy Storage Systems (BESS), by IEEE1547–2018 and German grid code standards. By analyzing grid-connected scenarios with five distinct PV control modes, the research introduces a novel protection methodology termed the Photovoltaic Overcurrent Relay (PVOCR). This method introduces a current-voltage characteristic to optimally coordinate Overcurrent Relays (OCRs), aiming to reduce their operational time and eliminate mis-coordination events. The proposed PVOCR is evaluated against standard inverse time, SOCR, and modern adaptive voltage, VOCR, relay schemes across various fault scenarios differing in type and location. Furthermore, the PVOCR scheme effectively operates across all PV inverter modes without experiencing miscoordination events, whereas the SOCR and VOCR schemes encountered such issues during the operation of Control 4. These results underscore the potential utility of the PVOCR methodology in enhancing the reliability and efficiency of protection systems in inverter-based DG networks.

Authors

Institutions

Publication Details

Journal
Electric Power Systems Research
Published
2024-08-30
DOI
https://doi.org/10.1016/j.epsr.2024.111025
Citations
4
Primary Topic
Islanding Detection in Power Systems
Type
article
Field-Weighted Citation Impact
0.83

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Highly sensitive protection scheme considering the PV operation control models

Naser El‐Naily, Feras Alasali, William Holderbaum, Hassen Loukil et al.
4 citations
Electric Power Systems Research
Islanding Detection in Power Systems
0.83
article

Highly sensitive protection scheme considering the PV operation control models

Naser El‐Naily, Feras Alasali, William Holderbaum, Hassen Loukil, Abdelaziz Salah Saidi, Aymen Flah, Hamza Albayadrah
article en
4 citations

Abstract

• A new protection methodology based on current-voltage characteristics. • Optimal OCR coordination under smart inverter control strategies. • Comparative analysis through the influence of diverse control techniques. The integration of distributed generation (DG) based on inverters into power systems has increased significantly, necessitating a thorough understanding of its impact on fault analysis and the performance of distribution networks' protection mechanisms. This study addresses this issue by examining how various inverter management modes influence protective relay systems within IEEE 9-bus redial and mesh networks, CIGRE and IEEE 33-bus networks featuring Photovoltaic (PV) farms and Battery Energy Storage Systems (BESS), by IEEE1547–2018 and German grid code standards. By analyzing grid-connected scenarios with five distinct PV control modes, the research introduces a novel protection methodology termed the Photovoltaic Overcurrent Relay (PVOCR). This method introduces a current-voltage characteristic to optimally coordinate Overcurrent Relays (OCRs), aiming to reduce their operational time and eliminate mis-coordination events. The proposed PVOCR is evaluated against standard inverse time, SOCR, and modern adaptive voltage, VOCR, relay schemes across various fault scenarios differing in type and location. Furthermore, the PVOCR scheme effectively operates across all PV inverter modes without experiencing miscoordination events, whereas the SOCR and VOCR schemes encountered such issues during the operation of Control 4. These results underscore the potential utility of the PVOCR methodology in enhancing the reliability and efficiency of protection systems in inverter-based DG networks.

Electric Power Systems ResearchVol. 237
Tunis University (TN), Hashemite University (JO), University of Benghazi (LY), National Engineering School of Tunis (TN), University of Business and Technology (SA), University of Salford (GB), Tunis El Manar University (TN), King Khalid University (SA)
University of Salford Manchester, King Khalid University, Hashemite University
Openalex Percentile: Top 27%
Islanding Detection in Power Systems
0.83
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.