Hypothermic Peritoneal Perfusion of Cold Oxygenated Perfluorocarbon May Improve the Efficacy of Extracorporeal Oxygenation: A Mathematical Model-Based Analysis

Abstract Circulation of perfluorocarbon (PFC) through corporeal cavities has received interest by virtue of its potential to supplement oxygenation via mechanical ventilation. However, the technology is not mature enough for clinical application, due to the knowledge gaps regarding the limiting factors hampering oxygen transport from PFC to blood. In this paper, we investigate a novel hypothesis that hypothermic peritoneal perfusion of cold oxygenated PFC may improve oxygenation of blood by facilitating the diffusion of oxygen from PFC to blood. Our hypothesis originates from physics-inspired insights that both hypothermia and PFC cooling may increase PFC-to-blood oxygen tension gradient: (i) hypothermia may decrease venous oxygen tension while (ii) cooling PFC may increase oxygen tension therein by increasing its oxygen solubility. Using a physics-based mathematical model capable of simulating oxygen tension responses to mechanical ventilation and peritoneal PFC perfusion under normothermic and hypothermic conditions, we analyzed the effect of hypothermic peritoneal cold PFC perfusion on blood oxygenation. The results predicted that peripheral oxygen saturation may be improved by 5–10% by peritoneal perfusion of oxygenated 15 °C PFC at 32 °C body temperature compared with peritoneal perfusion of oxygenated 37.5 °C PFC at 37.5 °C body temperature. The results also predicted that cooling PFC may play a more meaningful role than hypothermia. Pending the investigation of adverse impact of hypothermia and cold PFC on homeostasis, hypothermic cold PFC perfusion may improve peritoneal oxygenation by facilitating diffusion.

Authors

Institutions

Publication Details

Journal
Journal of Dynamic Systems Measurement and Control
Published
2024-08-30
DOI
https://doi.org/10.1115/1.4066390
Citations
2
Primary Topic
Respiratory Support and Mechanisms
Type
article
Field-Weighted Citation Impact
0.84
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hypothermic Peritoneal Perfusion of Cold Oxygenated Perfluorocarbon May Improve the Efficacy of Extracorporeal Oxygenation: A Mathematical Model-Based Analysis

Shelby Stewart, Parham Rezaei, Warren Naselsky, M. Awad et al.
2 citations
Journal of Dynamic Systems Measurement and Control
Respiratory Support and Mechanisms
0.84
article

Hypothermic Peritoneal Perfusion of Cold Oxygenated Perfluorocarbon May Improve the Efficacy of Extracorporeal Oxygenation: A Mathematical Model-Based Analysis

Shelby Stewart, Parham Rezaei, Warren Naselsky, M. Awad, Yejin Moon, Melissa Culligan, Joshua L. Leibowitz, Jin‐Oh Hahn, Behzad Kadkhodaeielyaderani, Stephen Stachnik, Nosayaba Enofe, Miao Yu, Grace M. Sarkar, Joseph S. Friedberg, Anna E. Shaw
article en
2 citations

Abstract

Abstract Circulation of perfluorocarbon (PFC) through corporeal cavities has received interest by virtue of its potential to supplement oxygenation via mechanical ventilation. However, the technology is not mature enough for clinical application, due to the knowledge gaps regarding the limiting factors hampering oxygen transport from PFC to blood. In this paper, we investigate a novel hypothesis that hypothermic peritoneal perfusion of cold oxygenated PFC may improve oxygenation of blood by facilitating the diffusion of oxygen from PFC to blood. Our hypothesis originates from physics-inspired insights that both hypothermia and PFC cooling may increase PFC-to-blood oxygen tension gradient: (i) hypothermia may decrease venous oxygen tension while (ii) cooling PFC may increase oxygen tension therein by increasing its oxygen solubility. Using a physics-based mathematical model capable of simulating oxygen tension responses to mechanical ventilation and peritoneal PFC perfusion under normothermic and hypothermic conditions, we analyzed the effect of hypothermic peritoneal cold PFC perfusion on blood oxygenation. The results predicted that peripheral oxygen saturation may be improved by 5–10% by peritoneal perfusion of oxygenated 15 °C PFC at 32 °C body temperature compared with peritoneal perfusion of oxygenated 37.5 °C PFC at 37.5 °C body temperature. The results also predicted that cooling PFC may play a more meaningful role than hypothermia. Pending the investigation of adverse impact of hypothermia and cold PFC on homeostasis, hypothermic cold PFC perfusion may improve peritoneal oxygenation by facilitating diffusion.

Journal of Dynamic Systems Measurement and ControlVol. 147(2)
University of Maryland, Baltimore (US), University of Maryland Medical Center (US), University of Maryland, College Park (US), Temple University (US)
Openalex Percentile: Top 24%
Respiratory Support and Mechanisms
0.84
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.