Accuracy of ultra-high resolution and virtual non-calcium reconstruction algorithm for stenosis evaluation with photon-counting CT: results from a dynamic phantom study

Evaluation of coronary stenosis with conventional CT is challenging at high heart rates. PC-CT allows for scanning with ECG-gated UHR and SR modes. UHR and VNCa images were compared in a dynamic phantom. UHR improves stenosis quantification up to 100 bpm. VNCa reconstruction improves stenosis evaluation up to 80 bpm.

Authors

Institutions

Publication Details

Journal
European Radiology Experimental
Published
2024-08-29
DOI
https://doi.org/10.1186/s41747-024-00482-w
Citations
13
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
2.40

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy of ultra-high resolution and virtual non-calcium reconstruction algorithm for stenosis evaluation with photon-counting CT: results from a dynamic phantom study

Nicola Fink, Emese Zsarnóczay, Ákos Varga‐Szemes, Thomas Allmendinger et al.
13 citations
European Radiology Experimental
Advanced X-ray and CT Imaging
2.40
article

Accuracy of ultra-high resolution and virtual non-calcium reconstruction algorithm for stenosis evaluation with photon-counting CT: results from a dynamic phantom study

Nicola Fink, Emese Zsarnóczay, Ákos Varga‐Szemes, Thomas Allmendinger, Junia Hagenauer, Daniel Pinos, U. Joseph Schoepf, Joseph P. Griffith, Milán Vecsey-Nagy, Tilman Emrich, Jim O’Doherty, Pál Maurovich‐Horvat
article en
13 citations

Abstract

Evaluation of coronary stenosis with conventional CT is challenging at high heart rates. PC-CT allows for scanning with ECG-gated UHR and SR modes. UHR and VNCa images were compared in a dynamic phantom. UHR improves stenosis quantification up to 100 bpm. VNCa reconstruction improves stenosis evaluation up to 80 bpm.

European Radiology ExperimentalVol. 8(1)
Semmelweis University (HU), Medical University of South Carolina (US), Friedrich-Alexander-Universität Erlangen-Nürnberg (DE), Johannes Gutenberg University Mainz (DE), LMU Klinikum (DE), University Medical Center of the Johannes Gutenberg University Mainz (DE), German Centre for Cardiovascular Research (DE), Siemens Healthineers (Germany) (DE), Ludwig-Maximilians-Universität München (DE)
Siemens Healthineers, Nemzeti Kutatási, Fejlesztési és Innovaciós Alap
Good health and well-being
Openalex Percentile: Top 11%
Advanced X-ray and CT Imaging
2.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Accuracy of ultra-high resolution and virtual non-calcium reconstruction algorithm for stenosis evaluation with photon-counting CT: results from a dynamic phantom study — Nicola Fink, Emese Zsarnóczay, et al. · European Radiology Experimental (2024) | TGRS Research Map | TGRS