Histological and scanning electron microscopy investigation of the effects of titanium surface modifications on osseointegration in rabbits

This study aimed to compare the novel Estaş Medical Anodization (EMA) surface treatment technique with the techniques commonly used in the literature and to examine their effects on osteointegration in the rabbit tibia. A total of 24 rabbits used in this study were divided into 3 groups, with 8 rabbits in each group. Using both tibias of all rabbits in the study, screws belonging to the control group were placed in the left tibia, and the right tibia belonging to the experimental group were placed. In the first 8 rabbits, a single experimental group in the right tibia were used; in the second 8 rabbits, 2 different experimental groups in the right tibia were used; and in the last 8 rabbits, 2 different experimental groups in the right tibia were used. Thus, 5 different experimental groups with 8 screws in each group and a separate control group were formed for each of them. EMA-treated surfaces were named 200-800 nm iris oxidation and 800-1200 nm gray oxidation according to the TiO2 layer thickness. Group 1 was implanted with mini-screws prepared with chemical etching+EMA iris oxidation, while group 2 was implanted with sandblasted, large-grit and acid-etched (SLA) mini screws treated with EMA gray oxidation. Group 3 was implanted with mini-screws treated with EMA gray oxidation, group 4 was implanted with mini-screws treated with chemical etching+micro-arc oxidation, and group 5 was implanted with mini-screws treated with chemical etching+EMA gray oxidation. The control group was implanted with mini-screws prepared with pure titanium. At the end of 6 weeks, osseointegration percentages were calculated and compared using histological and scanning electron microscope (SEM) analyses. The histological results confirmed the increase in osseointegration percentages in all experimental groups compared to those that received pure titanium implants (P values control group vs group 1=.005, control group vs group 2, 3, 4, 5=.001). The comparison between the groups revealed that the chemical etching+EMA gray oxidation modification technique (group 5) significantly increased osseointegration compared to the SLA+EMA gray oxidation technique (group 5 vs group 2 P=.016) and the chemical etching+EMA iris oxidation technique (group 5 vs group 1 Pp=.001). The EMA gray oxidation technique (group 3) significantly increased osseointegration compared to the chemical etching+EMA iris oxidation technique (group 1) (group 3 vs group 1 P=.043). The results of the SEM analysis showed that osseointegration was significantly increased in all experimental groups compared to that in the pure titanium (control) group (P values control group vs group 1, 2, 3=.001, control group vs Group 4,5=.006). The mean osseointegration percentage in the experimental groups was the highest in group 5, followed by group 4, group 3 and group 1 equally, and group 2. However, the differences among the experimental were not significant (group 1, group 2, group 3, group 4 vs group 5 P=.408). The EMA titanium surface modification techniques we developed significantly increased osseointegration compared to the pure titanium surface. The EMA gray oxidation technique seems to result in higher osseointegration rates than the EMA iris oxidation technique, and similar rates can be found with the SLA and chemical etching techniques. N/A.

Authors

Institutions

Publication Details

Journal
Acta Orthopaedica et Traumatologica Turcica
Published
2024-08-20
DOI
https://doi.org/10.5152/j.aott.2024.23135
Citations
1
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Histological and scanning electron microscopy investigation of the effects of titanium surface modifications on osseointegration in rabbits

İsmail Bilgin, Zekeriya Öztemür, Seyran Kılınç, Sefa Aktı et al.
1 citations
Acta Orthopaedica et Traumatologica Turcica
Bone Tissue Engineering Materials
0.18
article

Histological and scanning electron microscopy investigation of the effects of titanium surface modifications on osseointegration in rabbits

İsmail Bilgin, Zekeriya Öztemür, Seyran Kılınç, Sefa Aktı, Neşe Yeldir, Burak Aydın
article en
1 citations

Abstract

This study aimed to compare the novel Estaş Medical Anodization (EMA) surface treatment technique with the techniques commonly used in the literature and to examine their effects on osteointegration in the rabbit tibia. A total of 24 rabbits used in this study were divided into 3 groups, with 8 rabbits in each group. Using both tibias of all rabbits in the study, screws belonging to the control group were placed in the left tibia, and the right tibia belonging to the experimental group were placed. In the first 8 rabbits, a single experimental group in the right tibia were used; in the second 8 rabbits, 2 different experimental groups in the right tibia were used; and in the last 8 rabbits, 2 different experimental groups in the right tibia were used. Thus, 5 different experimental groups with 8 screws in each group and a separate control group were formed for each of them. EMA-treated surfaces were named 200-800 nm iris oxidation and 800-1200 nm gray oxidation according to the TiO2 layer thickness. Group 1 was implanted with mini-screws prepared with chemical etching+EMA iris oxidation, while group 2 was implanted with sandblasted, large-grit and acid-etched (SLA) mini screws treated with EMA gray oxidation. Group 3 was implanted with mini-screws treated with EMA gray oxidation, group 4 was implanted with mini-screws treated with chemical etching+micro-arc oxidation, and group 5 was implanted with mini-screws treated with chemical etching+EMA gray oxidation. The control group was implanted with mini-screws prepared with pure titanium. At the end of 6 weeks, osseointegration percentages were calculated and compared using histological and scanning electron microscope (SEM) analyses. The histological results confirmed the increase in osseointegration percentages in all experimental groups compared to those that received pure titanium implants (P values control group vs group 1=.005, control group vs group 2, 3, 4, 5=.001). The comparison between the groups revealed that the chemical etching+EMA gray oxidation modification technique (group 5) significantly increased osseointegration compared to the SLA+EMA gray oxidation technique (group 5 vs group 2 P=.016) and the chemical etching+EMA iris oxidation technique (group 5 vs group 1 Pp=.001). The EMA gray oxidation technique (group 3) significantly increased osseointegration compared to the chemical etching+EMA iris oxidation technique (group 1) (group 3 vs group 1 P=.043). The results of the SEM analysis showed that osseointegration was significantly increased in all experimental groups compared to that in the pure titanium (control) group (P values control group vs group 1, 2, 3=.001, control group vs Group 4,5=.006). The mean osseointegration percentage in the experimental groups was the highest in group 5, followed by group 4, group 3 and group 1 equally, and group 2. However, the differences among the experimental were not significant (group 1, group 2, group 3, group 4 vs group 5 P=.408). The EMA titanium surface modification techniques we developed significantly increased osseointegration compared to the pure titanium surface. The EMA gray oxidation technique seems to result in higher osseointegration rates than the EMA iris oxidation technique, and similar rates can be found with the SLA and chemical etching techniques. N/A.

Acta Orthopaedica et Traumatologica TurcicaVol. 58(4)
Sivas Cumhuriyet Üniversitesi (TR), Istanbul Medipol University (TR), Sivas State Hospital (TR), Bağcılar Eğitim ve Araştırma Hastanesi (TR)
Openalex Percentile: Top 53%
Bone Tissue Engineering Materials
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.