High-precision short-distance dual-comb ranging system without carrier-envelope-offset locking

In this paper, we propose a high-precision dual-comb ranging (DCR) method for short-distance measurement, avoiding carrier-envelope-offset locking. Cross-polarization detection is introduced, which makes better use of the intrinsic coherence of interferogram pairs over a short distance. We analyze the noise in the DCR system and propose a carrier-wave phase difference (CPD) calculation algorithm based on centroid extraction. The standard deviation of CPD is eight times less than that of the method we had proposed in a previous work, and the dynamic distance resolution is less than 10 nm at a distance of 10 µm. Besides, we compare the DCR result with the He-Ne laser interferometer from 0 to 4.8 mm, and the residual is found to be less than ±40 nm.

Authors

Publication Details

Journal
Optics Express
Published
2024-08-29
DOI
https://doi.org/10.1364/oe.535020
Citations
5
Primary Topic
Advanced Fiber Laser Technologies
Type
article
Field-Weighted Citation Impact
1.69

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-precision short-distance dual-comb ranging system without carrier-envelope-offset locking

Guanhao Wu, Yuetang Yang, Siyu Zhou, Shan Qian
5 citations
Optics Express
Advanced Fiber Laser Technologies
1.69
article

High-precision short-distance dual-comb ranging system without carrier-envelope-offset locking

Guanhao Wu, Yuetang Yang, Siyu Zhou, Shan Qian
article en
5 citations

Abstract

In this paper, we propose a high-precision dual-comb ranging (DCR) method for short-distance measurement, avoiding carrier-envelope-offset locking. Cross-polarization detection is introduced, which makes better use of the intrinsic coherence of interferogram pairs over a short distance. We analyze the noise in the DCR system and propose a carrier-wave phase difference (CPD) calculation algorithm based on centroid extraction. The standard deviation of CPD is eight times less than that of the method we had proposed in a previous work, and the dynamic distance resolution is less than 10 nm at a distance of 10 µm. Besides, we compare the DCR result with the He-Ne laser interferometer from 0 to 4.8 mm, and the residual is found to be less than ±40 nm.

Optics ExpressVol. 32(19)
National Natural Science Foundation of China
Openalex Percentile: Top 16%
Advanced Fiber Laser Technologies
1.69
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

High-precision short-distance dual-comb ranging system without carrier-envelope-offset locking — Guanhao Wu, Yuetang Yang, et al. · Optics Express (2024) | TGRS Research Map | TGRS