ACCURACY OF FOUR INTRAORAL SCANNERS IN FULL-ARCH SCANS
This research aims to evaluate the accuracy of four intraoral scanner models in full-arch scans. A master model was scanned using a high-precision desktop scanner, and a digital reference model was created. The master model was then scanned ten times by each of the intraoral scanners studied (TRIOS® 3, CEREC OmniCam, iTero™, and Medit i500). The digital models were compared to the master model using 3D measurement software. The analysis revealed significant differences in accuracy among the studied scanners, with the iTero™ scanner showing the best performance (p=0.0003). All scanners exhibited an average discrepancy of less than seventy micrometers in full-arch scans. These findings suggest that while all tested scanners are within clinically acceptable accuracy limits, the iTero™ may offer superior performance for full-arch digital impressions, potentially leading to improved outcomes in extensive dental rehabilitations.
Authors
- Fabiano Perez (ORCID: https://orcid.org/0000-0002-3399-1002)
- Sérgio Cândido Dias
- Geraldo Alberto Pinheiro de Carvalho (ORCID: https://orcid.org/0000-0002-6279-3558)
- Matheus Franco Lourenço (ORCID: https://orcid.org/0000-0001-9210-7232)
- Sílvio Mecca Júnior
Institutions
- Faculdade São Leopoldo Mandic (BR)
Publication Details
- Journal
- Revista CPAQV - Centro de Pesquisas Avançadas em Qualidade de Vida
- Published
- 2024-08-30
- DOI
- https://doi.org/10.36692/v16n2-77
- Primary Topic
- Dental materials and restorations
- Type
- article
- Field-Weighted Citation Impact
- 0.00